A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Expanded Polytetrafluoroethylene for Chordal Replacement: Preventing Knot Failure. | LitMetric

Expanded Polytetrafluoroethylene for Chordal Replacement: Preventing Knot Failure.

Ann Thorac Surg

Washington University in St. Louis School of Medicine and Department of Cardiothoracic Surgery, Barnes-Jewish Hospital, St. Louis, Missouri. Electronic address:

Published: December 2015

Purpose: Expanded polytetrafluoroethylene suture is commonly used for chordal replacement in mitral valve repair, but due to material characteristics, knots can unravel. Our aim was to determine the knot security, including how many throws are necessary to prevent knot failure, with Gore-Tex (W.L. Gore and Associates, Elkton, MD) and the newly available Chord-X (On-X Life Technologies Inc, Austin, TX).

Description: Knots were evaluated for maximal load based on: number of throws (6, 8, 10, and 12), tension to secure each throw (10%, 50%, and 85%) and suture type (Gore-Tex CV-5 and Chord-X 3-0). A physiologic force of 2 N was used for comparison.

Evaluation: We evaluated 240 knots. For all knots, the mean load to failure was 11.1 ± 5.8 N. Failure occurred due to unraveling in 141 knots (59%) at 7.1 ± 4.1 N and to breaking in 99 (41%) at 16.7 ± 2.0 N (p < 0.01). Gore-Tex failed at higher loads (12.6 ± 6.0 N vs 9.5 ± 5.2 N, p < 0.01); however, an equivalent number, 6 Gore-Tex and 6 Chord-X, unraveled at 2 N, all with fewer than 10 throws.

Conclusions: Expanded polytetrafluoroethylene has adequate strength to prevent breakage; however, a risk of knot unraveling at physiologic conditions exists when fewer than 10 throws are performed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6935365PMC
http://dx.doi.org/10.1016/j.athoracsur.2015.07.089DOI Listing

Publication Analysis

Top Keywords

expanded polytetrafluoroethylene
12
chordal replacement
8
knot failure
8
knots
5
polytetrafluoroethylene chordal
4
replacement preventing
4
knot
4
preventing knot
4
failure
4
failure purpose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!