Implants made of degradable magnesium alloys are a potential alternative to conventional orthopaedic implant materials, e.g. stainless steel or titanium. Intramedullary nails made of the magnesium alloy LAE442 were subjected to cyclic fatigue tests in both distilled water and Hank's Balanced Salt Solution (HBSS) at 37.5°C until implant failure or a limit of 500,000cycles was reached. In distilled water, four of the five nails were still intact after the end of the biomechanical test. In HBSS, a breakage within the first 70,000 bending cycles was observed. Additionally, the degradation rate of this alloy was determined in HBSS according to the weight loss method (0.24±0.12mmyear(-1)) and based on gas release (0.21±0.03mmyear(-1)) with a standard eudiometer. A cytotoxicity test with L929 cells was carried out in accordance with EN ISO 10993-5/12. This test demonstrated sufficient cell viability of the diluted extracts (50%, 25% and 12.5%). The relative metabolic activity of the 100% extract was reduced slightly below 70%, which is classified as a threshold value for cytotoxicity. In conclusion, this in vitro study indicates that intramedullary nails made of LAE442 may not have the required fatigue resistance for load-bearing applications and the development of a corrosion-protective coating may be necessary to prevent early failure of the implant.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.msec.2015.10.006 | DOI Listing |
Cureus
December 2024
Department of Surgery, Florida Atlantic University Charles E. Schmidt College of Medicine, Boca Raton, USA.
Subtrochanteric fractures in older patients are typically due to low-energy falls. The standard of care is intramedullary nailing. The Smith & Nephew Trigen Intertan (Memphis, TN, US) is an intramedullary nail with a novel design that incorporates two integrated compression screws.
View Article and Find Full Text PDFPurpose Of The Study: Intraarticular fractures of the distal femur rank among the most severe musculoskeletal injuries. Various treatment options, such as plate osteosynthesis or retrograde nailing, can be employed. This study aims to evaluate the clinical outcomes and complications of intraarticular distal femoral fractures treated with retrograde femoral nail, with particular emphasis on C3 fractures.
View Article and Find Full Text PDFEur J Orthop Surg Traumatol
January 2025
Department of Orthopaedic Surgery, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.
Purpose: Controversy remains about the ideal construct for certain olecranon fractures. The purpose of this study was to compare cost-effectiveness with the value driven outcomes tool between fixation strategies of olecranon fractures.
Methods: All surgically treated isolated proximal ulna fractures (CPT code 24,685) at a level 1 trauma center from 2013 to 2023 were retrospectively reviewed.
J Orthop Trauma
January 2025
Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, IN.
Objective: To evaluate mechanical failure rates of retrograde femoral nails in the treatment of distal femur fractures.
Methods: Design: Retrospective chart review.
Setting: Urban Academic Level 1 Trauma Center.
Sci Rep
January 2025
Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria.
Intramedullary nail fixation is a routine procedure for treatment of intertrochanteric fractures. Aseptic technique is vital for reducing postoperative complications, as intraoperative glove perforations increase the risk of surgical site infections. The aim of this study was to determine the incidence of surgical glove perforation during intramedullary nailing of intertrochanteric fractures and to identify surgery-specific steps at risk.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!