A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Knee stability after arthroscopic anterior cruciate ligament reconstruction using the middle third of the patellar ligament and quadrupled hamstring tendons grafts - A two-year follow-up. | LitMetric

Knee stability after surgical anterior cruciate ligament (ACL) reconstruction using quadrupled hamstring tendons graft (gracilis and semitendinosus) was compared with that using the middle third of the patellar ligament. All subjects participating in this study had ACL rupture diagnosed by clinical examination and MRI and underwent identical surgical procedure apart from the choice of graft. A total of 112 patients with either patellar ligament or quadrupled hamstring tendons graft were evaluated for 24 months following surgery. Patients were similar in terms of age, sex, activity level, knee instability level and rehabilitation programme. Clinical tests and a measuring instrument, the KT-1000 arthrometer, were used to evaluate knee stability after reconstruction. During the 24-month study there were no significant differences in clinical stability of the knee and the use of both grafts resulted in satisfactory knee stability. The difference between the groups according to the graft was noticed 6 months after reconstruction when the results obtained by a measuring instrument showed that knee stability was significantly higher with the patellar ligament graft (Fisher's exact test, p=0.022).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2015.10.056DOI Listing

Publication Analysis

Top Keywords

knee stability
20
patellar ligament
16
quadrupled hamstring
12
hamstring tendons
12
anterior cruciate
8
cruciate ligament
8
middle third
8
third patellar
8
ligament quadrupled
8
tendons graft
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!