Discordance in Grading Methods of Aortic Stenosis by Pre-Cardiopulmonary Bypass Transesophageal Echocardiography.

Anesth Analg

From the *Department of Anesthesiology, †Social Science Research Institute, and ‡Department of Biostatistics and Bioinformatics, Duke University, Durham, North Carolina.

Published: April 2016

Background: Current guidelines define severe aortic valve stenosis (AS) as an aortic valve area (AVA) ≤1.0 cm by the continuity equation and mean gradient (ΔPm) ≥ 40 mm Hg. However, these measurements can be discordant when classifying AS severity. Approximately one-third of patients with normal ejection fraction and severe AS by AVA have nonsevere AS by ΔPm when measured by preoperative transthoracic echocardiography (TTE). Given the use of positive pressure ventilation and general anesthesia in the pre-cardiopulmonary bypass (pre-CPB) period, we hypothesized that discordance between ΔPm and AVA during pre-CPB transesophageal echocardiography (TEE) would be higher than previously reported by TTE.

Methods: We retrospectively examined pre-CPB TEE data for patients who had aortic valve replacement, with or without coronary artery bypass grafting, from 2000 to 2012. Patients were excluded if they had ejection fraction <55%, emergency surgery, repeat sternotomy, moderate or severe mitral regurgitation, or severe aortic regurgitation. Only patients with both pre-CPB AVA and ΔPm measurements were included. Patients were grouped according to severity (mild, moderate, and severe) by AVA or ΔPm. Discordance was defined as disagreement between severities based on either parameter.

Results: A total of 277 patients met inclusion criteria. There were 227 patients with AVA ≤ 1.0 cm. The proportion of these patients with a ΔPm < 40 mm Hg was 54% (95% confidence interval, 47%-61%). The rate of discordance was significantly higher than the rate (37%; P < 0.001) found in previously reported analyses using TTE. Of the patients with a ΔPm ≥ 40 mm Hg, only 8% (n = 9/113) had a discordant AVA. In contrast, of the patients with ΔPm < 40 mm Hg, 80% (n = 131/164) had a discordant AVA.

Conclusions: We confirmed our hypothesis that grading AS by ΔPm and AVA during pre-CPB TEE exhibits higher discordance than reported for TTE by others. It remains unclear whether these discrepancies reflect the effect of general anesthesia, imaging modality (TTE versus TEE) differences, inaccuracies in AS grading cutoffs when applied to pre-CPB TEE, or selection bias of the surgical population.

Download full-text PDF

Source
http://dx.doi.org/10.1213/ANE.0000000000001099DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
pre-cardiopulmonary bypass
8
transesophageal echocardiography
8
ejection fraction
8
discordance grading
4
grading methods
4
aortic
4
methods aortic
4
aortic stenosis
4
stenosis pre-cardiopulmonary
4

Similar Publications

Background: Triglyceride-glucose-BMI (TyG-BMI) index is a surrogate marker of insulin resistance and an important predictor of cardiovascular disease. However, the predictive value of TyG-BMI index in the progression of non-severe aortic stenosis (AS) is still unclear.

Methods: The present retrospective observational study was conducted using patient data from Aortic valve diseases RISk facTOr assessmenT andprognosis modeL construction (ARISTOTLE).

View Article and Find Full Text PDF

Research establishing factors associated with duration of mechanical ventilation after Tetralogy of Fallot repair, is mainly based on population presenting at early infancy. There are fewer reports regarding repair after infancy, during childhood and preadolescence. To compare two groups of late TOF repair based on post-operative invasive mechanical ventilation duration and explore associations with pre-operative clinical markers of severity of right ventricular outflow tract obstruction.

View Article and Find Full Text PDF

Age-stratified Surgical Aortic Valve Replacement for Aortic Stenosis: What Does It Mean for Patients with Bicuspid Aortic Valve Disease?

J Cardiothorac Vasc Anesth

January 2025

Division of Congenital Cardiac Anesthesiology, University of Alabama at Birmingham School of Medicine, Birmingham, AL; Bruno Pediatric Heart Center, Children's of Alabama, Birmingham, AL. Electronic address:

View Article and Find Full Text PDF

Background: The optimal timing for percutaneous coronary intervention (PCI) in patients undergoing transcatheter aortic valve replacement (TAVR) is debatable.

Objectives: The aim of this study was to compare outcomes based on the timing of PCI in stable coronary artery disease patients undergoing TAVR.

Methods: Leveraging the STS/ACC TVT Registry and Medicare Linkage, we analyzed patients with stable coronary artery disease undergoing PCI and TAVR between 2015 and 2023 using the SAPIEN 3 balloon-expandable valve platform.

View Article and Find Full Text PDF

Coronary Events After Transcatheter Aortic Valve Replacement: Insights From the France TAVI Registry.

JACC Cardiovasc Interv

January 2025

Institut Cardiovasculaire Paris-Sud, Hôpital Privé Jacques Cartier, Ramsay-Santé, Massy, France. Electronic address:

Background: The prevalence of coronary artery disease in patients undergoing transcatheter aortic valve replacement (TAVR) is high. Treatment of a coronary events (CE) after TAVR can be technically challenging.

Objectives: The authors sought to assess the incidence and prognostic impact of CE after TAVR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!