Background: VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains.
Objective: To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation).
Methods: Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer's Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products.
Results: The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump solutions examined. All decreases in telavancin concentration were ≤2.7%. Comparison of each test sample solution to the corresponding glass control indicated no loss of active drug due to absorption by the elastomeric material of the pumps. The greatest increase in the amount of total degradants observed over the 8-day period was ~0.7 w/w%.
Conclusions: The results of this study indicate that telavancin remains chemically stable when diluted in the Intermate Infusion System and the Homepump Eclipse elastomeric pumps and stored at 2°C to 8°C for up to 8 days protected from light at the concentration range and dilution schemes evaluated.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4644242 | PMC |
http://dx.doi.org/10.1016/j.curtheres.2015.10.002 | DOI Listing |
J Oncol Pharm Pract
December 2024
School of Health and Social Care, Edinburgh Napier University, Edinburgh, UK.
Introduction: Exposure of healthcare workers to hazardous drugs may result in adverse health effects underscoring the importance of validating working procedures and safety precautions to minimise the risk. The objective was to monitor environmental contamination caused by the hazardous drug workflow: from drug vials, compounding process, to patient administration.
Methods: Surface wipe samples were collected from potentially contaminated surfaces in the compounding department and in the administration department.
JACC Case Rep
October 2024
Department of Cardiology, Christchurch Hospital, Te Whatu Ora Health NZ, Christchurch, New Zealand.
Objective: To describe a simple therapeutic intervention for persistent congestion in an advanced heart failure patient using a continuous intravenous furosemide infusion in the home setting with a non-powered elastomeric pump that can be managed by the patient.
Key Steps: Patient selected as a known intravenous furosemide responder with a supportive home environment. Shared care decision making with patient, cardiologist, heart failure nurse practitioner, palliative care physician, and general practitioner.
BMC Health Serv Res
October 2024
Department of Health Technology Assessment, Erasmus School of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, The Netherlands.
Background: Recent studies have underscored the potential of innovative administration methods to mitigate the capacity burden on healthcare systems, without compromising the quality of care. This study assessed and compared the resource utilization and associated costs of two distinct administration modes of immune checkpoint inhibitors: the innovative elastomeric pump and conventional intravenous infusion. This comparison can inform sustainable healthcare practices and healthcare decision-making to optimize treatment efficiency in an era of escalating healthcare demands.
View Article and Find Full Text PDFMicroorganisms
October 2024
Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium.
Although the addition of buffers provides improved stability to flucloxacillin (FLU) solutions, unbuffered solutions are often preferred in clinical practice. The first purpose of this study was to investigate whether a 50 mg/mL solution of FLU in normal saline is stable for 24 h at 33 °C so that it can be applied for outpatient parenteral antimicrobial therapy (OPAT) using portable elastomeric infusion pumps (PEIPs). When the PEIPs were stored in an oven at 33 °C and deflated over 24 h, the volume of the collected solution, pH, and FLU concentration were checked every 4 h.
View Article and Find Full Text PDFAntibiotics (Basel)
October 2024
Division of Internal Medicine, University Hospital Basel, 4031 Basel, Switzerland.
: Narrow-spectrum beta-lactam antibiotics such as benzylpenicillin and flucloxacillin are increasingly used in outpatient parenteral antimicrobial therapy (OPAT) programs to mitigate the adverse effects associated with broad-spectrum antibiotics. These beta-lactams require continuous administration via portable infusion devices during OPAT. However, the use of benzylpenicillin in OPAT requires special consideration because of its limited stability at elevated temperatures.