Cosyntropin-Stimulated Serum Free Cortisol in Healthy, Adrenally Insufficient, and Mildly Cirrhotic Populations.

J Clin Endocrinol Metab

Program in Reproductive and Adult Endocrinology (M.R., S.B.A., B.S.A., E.S., L.K.N.), The Eunice Kennedy Shriver National Institute of Child Health and Human Development, Biostatistics and Clinical Epidemiology Service (R.W.), Clinical Center, and Translational Hepatology Unit (A.T., T.H.), Liver Diseases Branch, The National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland 20892.

Published: March 2016

Context: Serum free cortisol (SFF) responses to cosyntropin simulation test (CST) may more accurately assess adrenal function than total cortisol (TF).

Objective: The objective of the study was to evaluate the diagnostic utility of SFF responses during a 250-μg CST.

Design: We recruited healthy volunteers (HV; n = 27), patients with primary and secondary adrenal insufficiency (n = 19 and n = 24, respectively), and subjects with Child-Pugh class A cirrhosis (CH; n = 15). Each received 250 μg cosyntropin with measurement of ACTH and corticosteroid binding globulin (CBG) at time 0 and TF and SFF at 0, 30, and 60 minutes. Salivary cortisol was measured at all time points in CH subjects.

Results: Peak SFF and TF were significantly higher in HVs vs both AI groups (P < .05). Peak SFF and TF (6.8 μg/dL vs 2.2 μg/dL; [188 nmol/L vs 62 nmol/L]; P < .01) were significantly higher in the secondary adrenal insufficiency vs primary adrenal insufficiency patients. The optimal peak SFF criterion to identify adrenal insufficiency patients vs HV was 0.9 μg/dL (25 nmol/L) (sensitivity of 95%, specificity of 100%). Mean CBG and albumin levels were similar among all four groups. CH patients had a higher peak SFF than HV (2.4 vs 2.0 μg/dL; P = .02. In the CH patients, peak salivary cortisol levels correlated well with peak SFF (rs = 0.84, P = .005). CBG levels were similar among the groups.

Conclusion: We provide normative data for SFF values in HV and AI during the CST. Normal CBG levels in mild cirrhosis did not affect the interpretation of the CST.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4803155PMC
http://dx.doi.org/10.1210/jc.2015-2285DOI Listing

Publication Analysis

Top Keywords

peak sff
20
adrenal insufficiency
16
sff
9
serum free
8
free cortisol
8
sff responses
8
secondary adrenal
8
salivary cortisol
8
sff μg/dl
8
insufficiency patients
8

Similar Publications

Background: Allogeneic stem cell transplantation (allo-SCT) is an efficacious treatment for hematologic malignancies but can be complicated by cardiac dysfunction and exercise intolerance impacting quality of life and longevity. We conducted a randomized controlled trial testing whether a multicomponent activity intervention could attenuate reductions in cardiorespiratory fitness and exercise cardiac function (co-primary end points) in adults undergoing allo-SCT.

Methods: Sixty-two adults scheduled for allo-SCT were randomized to a 4-month activity program (n=30) or usual care (UC; n=32).

View Article and Find Full Text PDF

Rare Genetic Variants in , , and Are Associated With Aortic Stenosis.

Circulation

November 2024

Cardiovascular Disease Initiative (J.T.R., S.J.J., S. Kany, X.W., S. Khurshid, P.T.E., J.P.P.), Cambridge, MA.

Article Synopsis
  • The study investigates how genetic variants affecting LDL-C levels influence the risk and severity of aortic stenosis (AS) by analyzing data from large cohorts in the UK Biobank and All of Us.
  • Researchers focused on protein-disrupting variants in genes related to LDL metabolism and their impact on diagnosed AS and aortic valve replacement.
  • Results showed that certain genetic variants lead to higher LDL-C levels and increased AS risk, while others resulted in lower LDL-C and a decreased risk of AS, highlighting the complex relationship between LDL-C and aortic valve health.*
View Article and Find Full Text PDF

Head-to-Head Comparison of Hepatic Vein and Superior Vena Cava Flow Velocity Waveform Analyses for Predicting Elevated Right Atrial Pressure.

Ultrasound Med Biol

September 2024

Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan.

Article Synopsis
  • - The study aimed to assess which Doppler profile (hepatic vein systolic filling fraction or SVC peak systolic/diastolic ratio) better indicated elevated right atrial pressure (RAP) in patients with cardiovascular diseases.
  • - It involved 193 patients, measuring Doppler profiles alongside cardiac catheterization, revealing that both profiles inversely correlated with RAP; however, SVC-S/D provided significantly better diagnostic accuracy than HV-SFF.
  • - Findings indicate that SVC-S/D is a more reliable measure for diagnosing elevated RAP compared to HV-SFF, with SVC-S/D showing additional diagnostic value beyond estimated RAP from inferior vena cava morphology.
View Article and Find Full Text PDF

The different paths to cultural convergence.

Behav Brain Sci

October 2023

Department of Psychosocial Science, SFF Centre for Early Sapiens Behaviour (SapienCE), University of Bergen, Bergen,

Morin envisions the adaptive landscape of graphic codes as an unfertile valley where writing rises as an isolated peak that humans managed to reach only on four occasions throughout all of history. By exploring the different paths to cultural convergence, we suggest an alternative landscape occupied by a mountain range of visual art systems. We conclude that graphic communication through visual art worked well enough to render writing contingent but not necessary in most cases.

View Article and Find Full Text PDF

An Improved Shape from Focus Method for Measurement of Three-Dimensional Features of Fuel Nozzles.

Sensors (Basel)

December 2022

Department of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.

The precise three-dimensional measurement of fuel nozzles is of great significance to assess the manufacturing accuracy and improve the spray and atomization performance. This paper proposes an improved fast shape from focus (SFF) method for three-dimensional measurement of key features of fuel nozzles. In order to ensure the measurement accuracy and efficiency of the SFF, the dispersion of the measured points from a standard flat plane was used to select the optimal combination of the focus measure operator, window size and sampling step size.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!