Quantitative, Organ-Specific Interscanner and Intrascanner Variability for 3 T Whole-Body Magnetic Resonance Imaging in a Multicenter, Multivendor Study.

Invest Radiol

From the *Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg; †Department of Clinical Radiology, Campus Grosshadern, Ludwig-Maximilians University, Munich; ‡Fraunhofer Institute for Medical Image Computing MEVIS, Bremen; §Institute of Neuroscience and Medicine, Jülich Research Centre, Jülich; ∥Department of Cardiology and Nephrology, HELIOS Clinic Berlin Buch, Berlin; ¶Institute for Community Medicine, Ernst-Moritz-Arndt University, Greifswald; #Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen; **Institute of Diagnostic Radiology, and ††Department of Epidemiology and Preventive Medicine, University Hospital Regensburg, Regensburg; ‡‡Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen; §§Department of Epidemiology, Helmholtz Centre for Infection Research, Braunschweig; ∥∥Department of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover; ¶¶O. Vogt Institute for Brain Research, Heinrich-Heine-University Düsseldorf, Düsseldorf; ##Department of Diagnostic and Interventional Radiology, University Hospital Klinikum rechts der Isar, Munich; ***Department of Radiology and Neuroradiology,University Medicine Greifswald, Ernst-Moritz-Arndt University, Greifswald; and †††Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany.

Published: April 2016

Introduction: Whole-body magnetic resonance (MR) imaging is increasingly implemented in population-based cohorts and clinical settings. However, to quantify the variability introduced by the different scanners is essential to make conclusions about clinical and biological data, and relevant for internal/external validity. Thus, we determined the interscanner and intrascanner variability of different 3 T MR scanners for whole-body imaging.

Methods: Thirty volunteers were enrolled to undergo multicentric, interscanner as well intrascanner imaging as part of the German National Cohort pilot studies. A comprehensive whole-body MR protocol was installed at 9 sites including 7 different MR scanner models by all 4 major vendors. A set of quantitative, organ-specific measures (n = 20; eg, volume of brain's gray/white matter, pulmonary trunk diameter, vertebral body height) were obtained in blinded fashion. Reproducibility was determined using mean weighted relative differences and intraclass correlation coefficients.

Results: All participants (44 ± 14 years, 50% female) successfully completed the imaging protocol except for two because of technical issues. Mean scan time was 2 hours and 32 minutes and differed significantly across scanners (range, 1 hour 59 minutes to 3 hours 12 minutes). A higher reproducibility of obtained measurements was observed for intrascanner than for interscanner comparisons (intraclass correlation coefficients, 0.80 ± 0.17 vs 0.60 ± 0.31, P = 0.005, respectively). In the interscanner comparison, mean relative difference ranged from 1.0% to 53.2%. Conversely, in the intrascanner comparison, mean relative difference ranged from 0.1% to 15.6%. There were no statistical differences for intrascanner and interscanner reproducibility between the different organ foci (all P ≥ 0.24).

Conclusions: While whole-body MR imaging-derived, organ-specific parameters are generally associated with good to excellent reproducibility, smaller differences are obtained when using identical MR scanner models by a single vendor.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0000000000000237DOI Listing

Publication Analysis

Top Keywords

quantitative organ-specific
8
interscanner intrascanner
8
intrascanner variability
8
whole-body magnetic
8
magnetic resonance
8
resonance imaging
8
scanner models
8
intraclass correlation
8
hours minutes
8
intrascanner interscanner
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!