Objectives: Before liver transplant, it is necessary to know the size of the organ in advance of the procedure. We studied the correlation between liver volumetric computed tomography results and liver weight.

Materials And Methods: Postmortem volumetric computed tomography was conducted on cadavers before autopsy, and 3-dimensional liver volume was estimated with semiautomated software. Liver weight was then determined at autopsy. Linear regression and univariate analysis of variance results were used to determine the accuracy of volumetric 3-dimensional computed tomography in estimating liver weight. We also used 2-dimensional liver sizes to design a 2-dimensional formula to estimate liver volume.

Results: We found that 3-dimensional volumetric computed tomography was able to accurately estimate liver weight (standard error = 157 g) with a liver density of 0.99 g/mL. Intraobserver and interobserver variabilities were small. The 2-dimensional formula estimated liver weight slightly less accurately (standard error = 212 g).

Conclusions: We conclude that liver weight can be estimated accurately with 3-dimensional volumetric computed tomography; estimates were more precise than with the 2-dimensional formula-based liver volume estimation. Volumetric computed tomography can be an important tool during preoperative workup before transplant surgery.

Download full-text PDF

Source
http://dx.doi.org/10.6002/ect.2015.0142DOI Listing

Publication Analysis

Top Keywords

computed tomography
28
volumetric computed
24
liver weight
24
liver
15
correlation liver
8
liver volumetric
8
tool preoperative
8
liver transplant
8
liver volume
8
2-dimensional formula
8

Similar Publications

Photothermal Coating on Zinc Alloy for Controlled Biodegradation and Improved Osseointegration.

Adv Sci (Weinh)

January 2025

Department of Prosthodontics, Peking University School and Hospital of Stomatology, No.22, Zhongguancun South Avenue, Haidian District, Beijing, 100081, China.

Zinc (Zn) and its alloys are promising biomaterials for orthopedic applications due to their degradability and mechanical properties. Zn plays a crucial role in bone formation, but excessive early release may cause cytotoxicity and inhibit osseointegration. To solve this, we developed a near-infrared (NIR) light-controlled polycaprolactone/copper-sulfur (PCL/CuS) coating that slows degradation and enhances osseointegration of Zn alloys.

View Article and Find Full Text PDF

Introduction The role of the condylar position in the correct functioning of the stomatognathic system has been the center of the study. Using cone-beam computed tomography (CBCT), this study looked at the three-dimensional (3D) position of the condylar bone in patients from Class I, Class II, Division 1, and Division 2. Materials and methods This cross-sectional, retrospective study was conducted using 102 CBCT records, with 34 records allocated to each category of malocclusion classification, such as dentoskeletal Class I, skeletal Class II, and dental Class II, Division 1 and 2.

View Article and Find Full Text PDF

Background: Low anterior resection (LAR) is the gold standard for curative cancer treatment in the middle and upper rectum. In radically operated patients, the local recurrence rates with total mesorectal excision (TME) after 5 and 10 years was<10%, with 80% in 5 years survival. Anastomotic leakage (AL) affects 4%-20% of patients who underwent LAR.

View Article and Find Full Text PDF

Objective: This study aimed to investigate how dynamic contrast-enhanced CT imaging signs correlate with the differentiation grade and microvascular invasion (MVI) of hepatocellular carcinoma (HCC), and to assess their predictive value for MVI when combined with clinical characteristics.

Methods: We conducted a retrospective analysis of clinical data from 232 patients diagnosed with HCC at our hospital between 2021 and 2022. All patients underwent preoperative enhanced CT scans, laboratory tests, and postoperative pathological examinations.

View Article and Find Full Text PDF

Purpose: The study aimed to measure the distance from the cementoenamel junction (CEJ) to the alveolar bone crest on both the buccal and lingual sides of the anterior mandibular teeth utilizing cone beam computed tomography (CBCT).

Materials And Methods: Cone-beam computed tomography (CBCT) was utilized to measure the distance between CEJ and the alveolar bone crest on both the buccal and lingual sides of the mandible's anterior teeth.

Results: The mean of the distance on buccal side for the central, lateral, and canine teeth were (1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!