Purpose: Colostrum has been proposed to treat severe dryness and problematic eye lesions showing a beneficial effect. The aim of the study was to investigate the effect of 2-fucosyl-lactose, a natural sugar present in the human colostrum, in an experimental dry eye.

Methods: Dry eye was induced in adult male New Zealand albino rabbits by topical administration of 1% atropine. Tear volume (Schirmer's test), tear film breakup time (TBUT), corneal staining and tear osmolarity were assessed. Fucosyl-lactose eye drops was instilled at different concentrations (0.01, 0.1, and, 1%).

Results: After 24 h from first atropine administration, tear volume and TBUT values were significantly improved in groups treated with 2-fucosyl-lactose in a dose-dependent manner. Tear volume increased from 5.25 to 10.75 mm and TBUT values from 8.75 to 34.5 s with 0.01% or 1% 2-fucosyl-lactose treatment, respectively. No changes were observed in terms of corneal staining among the all groups treated with 2-fucosyl-lactose. Atropine instillation caused an increase of tear osmolarity (428 mOsm/L), which was reversed by topical treatment with 2-fucosyl-lactose at all doses.

Conclusion: The present study demonstrated that 2-fucosyl-lactose, a human milk oligosaccharide, has protective effect on tear film stability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4649014PMC
http://dx.doi.org/10.3389/fphar.2015.00280DOI Listing

Publication Analysis

Top Keywords

tear volume
12
milk oligosaccharide
8
dry eye
8
tear film
8
corneal staining
8
tear osmolarity
8
tbut values
8
groups treated
8
treated 2-fucosyl-lactose
8
tear
7

Similar Publications

Using a laser-scribed (direct printing) technique, we have fabricated an enzymeless, mediatorless, and paper-interfaced electrochemical device (P-LSG) for uric acid detection on a flexible polyimide sheet. Various paper substrates were investigated, and it was found that Whatman filter paper-1 is promising to obtain the best electrochemical signals at the small volume of electrolyte, i.e.

View Article and Find Full Text PDF

BACKGROUND The 6-item Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) is a method for evaluating disease activity in ankylosing spondylitis (AS). This study included 78 patients with active and inactive AS and aimed to evaluate anterior and posterior segment ocular changes. MATERIAL AND METHODS Seventy-eight patients and 70 control subjects were enrolled in this study.

View Article and Find Full Text PDF

Dry eye disease and morphological changes in the anterior chamber in people with cystic fibrosis.

J Cyst Fibros

January 2025

Pulmonology Department, Regional University Hospital of Malaga, Department of Medicine and Dermatology, University of Malaga, Biomedical Research Institute of Malaga (IBIMA) - Bionand Platform, Malaga, Spain. Electronic address:

Background: Cystic fibrosis (CF) is caused by variants in a gene that encodes a protein essential for water and ion transport in the epithelial cells of exocrine organs. Given the possible relationship of this protein and conjunctival and corneal epithelium, the aim of this study was to evaluate ophthalmologic alterations in people with CF.

Methods: Forty-five people with CF underwent pulmonary evaluation including inflammatory score (IS).

View Article and Find Full Text PDF

Purpose: To (1) systematically assess which orthobiologic agents are being used in acetabular labral repairs and (2) report all available outcomes for patients undergoing operative management for labral repairs with orthobiologic agents.

Methods: The PubMed, Embase, and Cochrane databases were queried in August 2023. Articles were included if they used an orthobiologic agent during hip arthroscopy for acetabular labral repair and reported functional outcomes.

View Article and Find Full Text PDF

Study on the Abrasive Blasting Mechanism of Solder Welded 304V Wire in Vascular Intervention.

Micromachines (Basel)

November 2024

Department of Vascular Surgery, General Surgery Clinical Center, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, 100 Haining Road, Shanghai 200080, China.

The solder burrs on the 304V wire surface can easily scratch the vascular tissue during interventional treatment, resulting in complications such as medial tears, bleeding, dissection, and rupture. Abrasive blasting is often used to remove solder burr and obtain a smooth surface for the interventional device. This study conducted an abrasive blasting experiment to explore the effects of process parameters (air pressure, lift-off height, abrasive volume, and abrasive type) on processing time, surface roughness, and mechanical properties to reveal the material removal mechanism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!