Hemolysis should lead to changes in test results. Our study evaluated the impact of hemolysis on 26 blood measurements of stat biochemistry markers (sodium, potassium, chloride, urea, creatinine, glucose, total protein, calcium, magnesium, inorganic phosphorus, uric acid, C-reactive protein, total bilirubin, ASAT, ALAT, LDH, creatine kinase, alkaline phosphatase, γ glutamyl-transferase, lipase, alcohol, iron, β hCG, troponins, natriuretic peptides) determined with 13 different types of instruments in 17 hospital laboratories. Four pools of samples (collected from lithium heparin or EDTA or sodium fluoride tubes, according to the measured parameters) were overloaded with five increasing concentrations of whole blood lysate (final concentration from 0 to 2.000 mg/dL). Replication was performed for each assay, average values were calculated and differences between results with and without lysate were analyzed. A difference exceeding the square root of the sum of both squared analytic and biologic imprecisions for each analyte, was judged to be significant. Except homogeneous and expected impact of hemolysis on certain parameters like potassium, LDH... (due to their intra-erythrocyte concentration) a heterogeneous effect was found for other parameters, according to the analyzer and/or to the methodology. In summary, this study confirms the importance of mastering the measurement of the hemolysis and leads to several recommendations: (i) biologists should have a good knowledge of the impact of hemolysis on the measurements they perform, depending on their chosen analyzers; (ii) if an interference is noticed, it is recommended to add to the result a relevant comment and to check that the comment is properly edited in the laboratory computer software and appears on printed and transmitted results.

Download full-text PDF

Source
http://dx.doi.org/10.1684/abc.2015.1090DOI Listing

Publication Analysis

Top Keywords

impact hemolysis
12
hemolysis
5
[hemolysis interferences
4
interferences frequently
4
frequently required
4
required stat
4
stat analysis
4
analysis french
4
french multicentric
4
multicentric study]
4

Similar Publications

Hematologic Complications of Pregnancy.

Eur J Haematol

January 2025

Division of Hematology and Medical Oncology, Oregon Health & Science University, Portland, Oregon, USA.

Hematologic complications are common in pregnancy and can significantly impact both maternal and fetal health. Recognizing and treating these complications can be challenging due to the limited evidence available to guide clinical consultants. Iron deficiency anemia is the most prevalent hematologic issue in pregnancy and often occurs due to increased maternal blood volume and the nutritional demands of the growing fetus.

View Article and Find Full Text PDF

Background: Alzheimer's disease (AD) is the most common cause of dementia, and the fifth leading cause of death for those 65 and older. Brain changes in AD begin 10-20 years before symptoms appear, yet markers for early brain changes are lacking. We discovered and validated miRNAs in human cerebrospinal fluid (CSF) that differentiate AD from Controls.

View Article and Find Full Text PDF

Epicatechin Influence on Biochemical Modification of Human Erythrocyte Metabolism and Membrane Integrity.

Int J Mol Sci

December 2024

Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Viale Ferdinando Stagno d'Alcontres 31, 98166 Messina, Italy.

Red blood cells (RBCs) are the main cells of the blood, perform numerous functions within the body and are in continuous contact with endogenous and exogenous molecules. In this context, the study aims to investigate the effect of epicatechin (EC) (flavan-3-ols) on the erythrocytes, analyzing the protective effect of the molecule and the action exerted on metabolism and RBC membrane. The effect of EC on RBC viability has been evaluated through the change in hemolysis and methemoglobin, assessing caspase 3 activity and performing a cytofluorometric analysis.

View Article and Find Full Text PDF

Cell-free hemoglobin released from hemolysis induces programmed cell death through iron overload and oxidative stress in grass carp (Ctenopharyngodon idella).

Fish Shellfish Immunol

January 2025

Guangdong Provincial Water Environment and Aquatic Products Security Engineering Technology Research Center, Guangzhou Key Laboratory of Aquatic Animal Diseases and Waterfowl Breeding, College of Animal Sciences and Technology, Zhongkai University of Agriculture and Engineering, Guangzhou, Guangdong Province, 510222, China. Electronic address:

Intravascular hemolysis releases hemoglobin (Hb) from red blood cells under specific conditions, yet the effect of hemolysis in aquaculture systems remain poorly understood. In this study, a continuous hemolysis model for grass carp was established by injection of phenylhydrazine (PHZ) to investigate the mechanistic impacts of sustained hemolysis. PHZ-induced hemolysis altered liver color, and subsequent hematoxylin and eosin staining revealed substantial Hb accumulation in the head kidney, accompanied by inflammatory cell infiltration and vacuolization in liver tissue.

View Article and Find Full Text PDF

Ligand-binding assays validated for quantitative bioanalysis of a novel antibody-drug conjugate in monkey serum and related application in a nonclinical study.

J Pharmacol Toxicol Methods

December 2024

Department of Immunoassay and Immunochemistry, Center for Drug Safety Evaluation and Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China; State Key Laboratory of Drug Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China; University of Chinese Academy of Sciences, Beijing 101408, China; Zhongshan Institute for Drug Discovery, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Zhongshan 528400, China. Electronic address:

Background: Antibody-drug conjugates (ADCs) are an emerging class of targeted therapeutics and are receiving growing attention in the pharmaceutical field. Here we aimed to validate two ligand binding assays for the quantitation of GQ1001, an ADC made of Trastuzumab site-specifically conjugated with DM1, in cynomolgus monkey serum, and then apply the validated assays to a nonclinical study.

Methods: The quantitative methods for conjugated GQ1001 and total GQ1001 were validated against regulatory guidance documents on bioanalytical method validation under a Good Laboratory Practice (GLP)-compliant environment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!