Perfusion imaging is the most applied modality for the assessment of acute stroke. Parameters such as Cerebral Blood Flow (CBF), Cerebral Blood volume (CBV) and Mean Transit Time (MTT) are used to distinguish the tissue infarct core and ischemic penumbra. Due to lack of standardization these parameters vary significantly between vendors and software even when provided with the same data set. There is a critical need to standardize the systems and make them more reliable. We have designed a uniform phantom to test and verify the perfusion systems. We implemented a flow loop with different flow rates (250, 300, 350 ml/min) and injected the same amount of contrast. The images of the phantom were acquired using a Digital Angiographic system. Since this phantom is uniform, projection images obtained using DSA is sufficient for initial validation. To validate the phantom we measured the contrast concentration at three regions of interest (arterial input, venous output, perfused area) and derived time density curves (TDC). We then calculated the maximum slope, area under the TDCs and flow. The maximum slope calculations were linearly increasing with increase in flow rate, the area under the curve decreases with increase in flow rate. There was 25% error between the calculated flow and measured flow. The derived TDCs were clinically relevant and the calculated flow, maximum slope and areas under the curve were sensitive to the measured flow. We have created a systematic way to calibrate existing perfusion systems and assess their reliability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4664206 | PMC |
http://dx.doi.org/10.1117/12.2081471 | DOI Listing |
Soft Robot
January 2025
Department of Automation, Shanghai Jiao Tong University, Shanghai, China.
Small-scale soft robots, despite their potential for adaptability in unknown environments, often encounter performance constraints due to inherent limitations within soft actuators and compact bodies. To address this problem, we proposed a fast-moving soft robot driven by electroactive materials. The robot combines the advantages of dielectric elastomer actuators (DEAs) and shape memory alloy (SMA) spring actuators, enabling its high-performance multi-modal locomotion in a small and lightweight design.
View Article and Find Full Text PDFWorld Neurosurg
January 2025
Department of Orthopedics, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China. Electronic address:
Background: Increased systemic bone mineral density has been reported in patients with ossification of the posterior longitudinal ligament (OPLL). This study investigated the differences in vertebral Hounsfield units (HU) values between the bridged and non-bridged groups of patients with OPLL of the cervical spine at the ossification-related segments.
Methods: A total of 436 ossification-related segments from 157 patients were involved in the study.
Sci Rep
January 2025
Department of Geotechnical Engineering, School of Civil Engineering, Tongji University, Shanghai, 200000, China.
This study investigates the vulnerability of expansive soil slopes to destabilization and damage, particularly under intense rainfall, due to their heightened sensitivity to moisture. Focusing on a project in Yunnan Province, numerical simulation software is employed to address slope stability challenges. Meanwhile, the soil mechanical parameters of this study were acquired through experimentation.
View Article and Find Full Text PDFEnviron Monit Assess
December 2024
Chemistry Department, Faculty of Art and Science, Yıldız Technical University, 34220, Istanbul, Türkiye.
In this study, a preconcentration strategy based on Ni(OH) nanoflowers (NFs) was developed for the extraction/separation of bismuth ions from environmental water samples before the determination by flame atomic absorption spectrometry (FAAS). The homogeneous coprecipitation method was employed for the synthesis of the flower-shaped Ni(OH) and used as an adsorbent for the preconcentration of bismuth. The extraction variables were determined by a univariate optimization strategy to obtain maximum extraction performance.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Mechanical and Aerospace Engineering, School of Engineering, University of Petroleum & Energy Studies (UPES), Dehradun, Uttarakhand, 248007, India.
This numerical investigation examines the performance and exergy analysis of parabolic trough solar collectors, focusing on the substitution of the conventional circular absorber with a rhombus-shaped absorber. By evaluating the thermal and fluid dynamics properties, this study aims to identify improvements in overall system performance and efficiency. This numerical study conducts a comprehensive thermal analysis of parabolic trough solar collectors by comparing a rhombus-shaped absorber with a conventional circular absorber.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!