Comparison of Traditional and Integrated Digital Anesthetic Vaporizers.

J Am Assoc Lab Anim Sci

Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.

Published: November 2015

Recent efforts have focused on mitigating anesthetic gas emissions during laboratory animal experiments. A recently developed, digitally controlled, integrated digital vaporizer (IDV) using a syringe pump has been designed to use and administer anesthetic gas to mice and rats more efficiently. The entire IDV system can be placed on a laboratory bench, requires fewer charcoal filters to act as passive scavengers when used at a low gas flow rate, and does not need compressed gas to operate, a requirement for traditional passive systems. The objective of this study was to compare isoflurane usage between a traditional vaporizer (TdV) and an IDV system at both the same settings and those recommended by the manufacturer. We used 10 C57BL/6 male mice and administered isoflurane through either nose cones or tracheal tubes connected to a pulsatile ventilator. The results showed that isoflurane usage is highly dependent on the flow rate of the carrier gas, but the IDV system was more precise and handled low flow rates (150 mL/min) better than did the TdV system. We observed only slight differences in heart rate, respiration rate, core body temperature, time to loss of the righting reflex, and recovery time between group averages for both systems when set to manufacturer-recommended settings. Although observed decreased levels of waste anesthetic gas at low flow rates are expected from the IDV system, further work is needed to assess environmental anesthetic gas levels and exposure to laboratory personnel.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4671791PMC

Publication Analysis

Top Keywords

anesthetic gas
16
idv system
16
integrated digital
8
flow rate
8
isoflurane usage
8
low flow
8
flow rates
8
gas
7
anesthetic
5
idv
5

Similar Publications

Carbon dioxide gas emboli is a potentially fatal complication that occurs more frequently during laparoscopic hepatectomy compared to other laparoscopic surgeries. The patient featured in this report had massive gas embolism confirmed by intraoperative transesophageal echocardiography (TEE) that were associated with episodes of severe hypoxemia, hemodynamic instability, and right ventricular failure requiring conversion to open hepatectomy. Abrupt abdominal decompression resulted in massive hemorrhage from a previously undetected defect in the middle hepatic vein.

View Article and Find Full Text PDF

To investigate the efficacy and mechanisms of fractional CO2 laser treatment for Vaginal Relaxation Syndrome (VRS) combined with recurrent bacterial vaginitis. Patients with VRS and recurrent bacterial vaginitis were randomly assigned to an intervention group (n = 60) receiving fractional CO2 laser therapy in addition to metronidazole, or a control group (n = 60) receiving metronidazole alone. Post-treatment assessments included vaginal relaxation, vaginal health index (VHI) scores, lactobacilli distribution, vaginal pH, recurrence rates, and the correlation between lactobacilli distribution and VHI.

View Article and Find Full Text PDF

As one of the most commonly used general anesthetics (GAs) in surgery, numerous studies have demonstrated the detrimental effects of sevoflurane exposure on myelination in the developing and elderly brain. However, the impact of sevoflurane exposure on intact myelin structure in the adult brain is barely discovered. Here, we show that repeated sevoflurane exposure, but not single exposure, causes hypomyelination and abnormal ultrastructure of myelin sheath in the prefrontal cortex (PFC) of adult male mice, which is considered as a critical brain region for general anesthesia mediated consciousness change.

View Article and Find Full Text PDF

Background: Inhalational anesthetic agents are a major source of potent greenhouse gases in the medical sector, and reducing their emissions is a readily addressable goal. Nitrous oxide (NO) has a long environmental half-life relative to carbon dioxide combined with a low clinical potency, leading to relatively large amounts of NO being stored in cryogenic tanks and H cylinders for use, increasing the chance of pollution through leaks. Building on previous findings, Stanford Health Care's (SHC's) NO emissions were analyzed at 2 campuses and targeted for waste reduction as a precursor to system-wide reductions.

View Article and Find Full Text PDF

Fractional CO Laser to Treat Surgical Scars: A System Review and Meta-Analysis on Optimal Timing.

J Cosmet Dermatol

January 2025

Department of Aesthetic Plastic Surgery, West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China.

Background: Surgical scars with textural changes can be disfiguring and uncomfortable for patients. Various laser therapies have shown promise in softening and flattening these scars. Therefore, the authors conducted a systematic review and meta-analysis on the efficacy of fractional CO laser in treating surgical scars.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!