Objectives: The aim of this study was to investigate the hemodynamic performance of a transcatheter heart valve (THV) deployed at different valve-in-valve positions in an in vitro model using a small surgical bioprosthesis.

Background: Patients at high surgical risk with failing 19-mm surgical aortic bioprostheses are not candidates for valve-in-valve transcatheter aortic valve replacement, because of risk for high transvalvular pressure gradients (TVPGs) and patient-prosthesis mismatch.

Methods: A 19-mm stented aortic bioprosthesis was mounted into the aortic chamber of a pulse duplicator, and a 23-mm low-profile balloon-expandable THV was deployed (valve-in-valve) in 4 positions: normal (bottom of the THV stent aligned with the bottom of the surgical bioprosthesis sewing ring) and 3, 6, and 8 mm above the normal position. Under controlled hemodynamic status, the effect of these THV positions on valve performance (mean TVPG, geometric orifice area, and effective orifice area), thrombotic potential (sinus shear stress), and migration risk (pullout force and embolization flow rate) were assessed.

Results: Compared with normal implantation, a progressive reduction of mean TVPG was observed with each supra-annular THV position (normal: 33.10 mm Hg; 3 mm: 24.69 mm Hg; 6 mm: 19.16 mm Hg; and 8 mm: 12.98 mm Hg; p < 0.001). Simultaneously, we observed increases in geometric orifice area (normal: 0.83 cm(2); 8 mm: 1.60 cm(2); p < 0.001) and effective orifice area (normal: 0.80 cm(2); 8 mm: 1.28 cm(2); p < 0.001) and reductions in sinus shear stresses (normal: 153 dyne/cm(2); 8 mm: 40 dyne/cm(2); p < 0.001), pullout forces (normal: 1.55 N; 8 mm: 0.68 N; p < 0.05), and embolization flow rates (normal: 32.91 l/min; 8 mm: 26.06 l/min; p < 0.01).

Conclusions: Supra-annular implantation of a THV in a small surgical bioprosthesis reduces mean TVPG but may increase the risk for leaflet thrombosis and valve migration. A 3- to 6-mm supra-annular deployment could be an optimal position in these cases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2015.08.028DOI Listing

Publication Analysis

Top Keywords

orifice area
16
normal
9
thv deployed
8
deployed valve-in-valve
8
valve-in-valve positions
8
small surgical
8
surgical bioprosthesis
8
geometric orifice
8
effective orifice
8
sinus shear
8

Similar Publications

To report the procedure of an alternative modified transvaginal repair technique (V-NOTES) and their outcomes in apical vesicovaginal fistula. Between January 2020 and January 2023, gynecological procedures resulted in the diagnosis of apical VVFs in 26 patients, 17 of whom had undergone transvaginal repair of apical vesicovaginal fistula via vaginal V-NOTES. Those patients were contacted and followed up.

View Article and Find Full Text PDF
Article Synopsis
  • Cardiac resynchronization therapy (CRT) improves functional mitral regurgitation (FMR) by coordinating heart muscle segments, especially between papillary muscles, beyond just boosting left ventricular (LV) performance.
  • Eighteen patients with dilated cardiomyopathy underwent tests to measure heart function, and biventricular pacing showed a significant reduction in mitral regurgitation despite some patients showing no change in LV pressure.
  • The study concludes that CRT effectively lowers FMR independently of LV systolic function improvements, highlighting the importance of understanding its mechanisms for better treatment outcomes.
View Article and Find Full Text PDF

Clinical feasibility study of transcatheter edge-to-edge mitral valve repair in dogs with the canine V-Clamp device.

Front Vet Sci

December 2024

Department of Clinical Sciences and James L. Voss Veterinary Teaching Hospital, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO, United States.

Objective: To determine procedural feasibility, safety, and short-term efficacy in dogs with severe degenerative mitral regurgitation (MR) undergoing transcatheter edge-to-edge repair (TEER) with a canine-specific device.

Design: Prospective, single-arm (uncontrolled), single-institution clinical feasibility study.

Animals: Fifty client-owned dogs with severe degenerative MR operated over a 28-month period.

View Article and Find Full Text PDF

Double-bundle (DB) anterior cruciate ligament (ACL) reconstruction has biomechanical advantages over single-bundle reconstruction. However, most studies perform the DB reconstruction with 2 femoral tunnels, which fails to provide an entire femoral footprint for ACL reconstruction. In this study, we describe a femoral double-bundle footprint technique for ACL reconstruction, named the tendon groove technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!