Tc-99m imaging in thyroidectomized differentiated thyroid cancer patients immediately before I-131 treatment.

Nucl Med Commun

aDepartment of Nuclear Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei Departments of bGeneral Surgery cNuclear Medicine, Changhua Christian Hospital, Changhua dDepartment of Nuclear Medicine and Anesthesiology, Chi-Mei General Hospital, Tainan, Taiwan.

Published: February 2016

Purpose: The aim of this study was to evaluate the clinical role of technetium-99m pertechnetate (Tc-99m) imaging in thyroidectomized differentiated thyroid cancer patients immediately before radioiodine-131 (I-131) treatment (Tx).

Patient And Methods: Eighty-six consecutive post-total-thyroidectomy patients (15 men, 71 women; mean age: 46.8 years) with pathologically diagnosed differentiated thyroid cancer were retrospectively studied. Tc-99m imaging immediately before I-131 Tx using both patient-based and lesion-based measurements were analyzed and were further compared with those of post-Tx I-131 whole-body scans.

Results: For patients with unequivocally positive Tc-99m uptake, the sensitivity was 77% (patient-based) and 59% (site-based). The positive predictive value (PPV) was 100% for both patient-based and site-based measurements. If equivocal Tc-99m uptake was counted as positive, the sensitivity was 83 and 67%, and the PPV was 100 and 99% for patient-based and site-based measurements, respectively.

Conclusion: (a) To increase sensitivity yet maintaining high PPV, equivocal Tc-99m uptake should be considered a positive finding. (b) The nearly 100% PPV of Tc-99m imaging immediately before I-131 Tx for remnant detection suggests that Tc-99m imaging not only serves as an alternative to low-dose I-131 scanning in the low-risk post-thyroidectomy patients but also provides a clue for the subsequent I-131 therapeutic dosage and even for the outcome prediction.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MNM.0000000000000426DOI Listing

Publication Analysis

Top Keywords

tc-99m imaging
20
differentiated thyroid
12
thyroid cancer
12
tc-99m uptake
12
tc-99m
8
imaging thyroidectomized
8
thyroidectomized differentiated
8
cancer patients
8
i-131 treatment
8
imaging i-131
8

Similar Publications

Purpose Of Review: This review evaluates recent advancements in Technetium-99 m pyrophosphate (99mTc-PYP) imaging for transthyretin amyloid cardiomyopathy (ATTR-CM). We summarize the advantages of single-photon emission computed tomography (SPECT) over planar imaging, the potential impact of quantitative methods, and emerging data for quantifying response to therapy.

Recent Findings: The current literature demonstrates the superior diagnostic accuracy of SPECT compared with planar imaging in 99mTc-PYP studies.

View Article and Find Full Text PDF

Primary hyperparathyroidism (PHPT) is a prevalent clinical condition characterized by an inappropriate secretion of parathyroid hormone (PTH). It is most often caused by one or more parathyroid adenomas, which can, in rare cases, be ectopically located. Ectopic adenomas can pose a diagnostic challenge, lead to treatment delay, and be a common cause of recurrent hypercalcemia after parathyroidectomy.

View Article and Find Full Text PDF

Objective: To assess the efficacy and safety of subcutaneous perispinal infiltration of low dose of triamcinolone and lidocaine indicated for pain control in patients with cervical osteoarthritis (COA).

Methods: Patients with symptomatic COA resistant to conventional treatment including anti-inflammatory drugs, analgesics, and physical therapy were included. Technetium-99 m pyrophosphate (99mTc-PYP) scintigraphy and computerized tomography (CT) fusion scans images were used for diagnosis of COA and as a guide for level(s) of infiltration(s).

View Article and Find Full Text PDF

Background: Kidney depth significantly affects the accuracy of glomerular filtration rate (GFR) measurement, and hydronephrosis-induced morphological changes further challenge its estimation through traditional formulas. This study evaluated the rotation method's efficacy in correcting kidney depth and depth difference during Tc-99m diethylenetriamine pentaacetic acid (DTPA) renal dynamic imaging for GFR assessment.

Methods: This study analyzed 66 individuals treated at First Hospital of Shanxi Medical University with unilateral hydronephrosis between January 2022 and June 2023.

View Article and Find Full Text PDF

Background And Objective: Diabetic neuropathy significantly elevates the risk of foot ulceration and lower-limb amputation, underscoring the need for precise assessment of tissue perfusion to optimize management. This narrative review explores the intricate relationship between sympathetic nerves and tissue perfusion in diabetic neuropathy, highlighting the important role of autonomic neuropathy in blood flow dynamics and subsequent compromises in tissue perfusion. The consequences extend to the development of diabetic peripheral neuropathy and related foot complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!