Quantitative assessment of contact and non-contact lateral force calibration methods for atomic force microscopy.

Ultramicroscopy

School of Mechanical Engineering, University of Ulsan, 93 Daehak-ro, Nm-gu, Ulsan, 44610 South Korea. Electronic address:

Published: February 2016

Atomic Force Microscopy (AFM) has been widely used for measuring friction force at the nano-scale. However, one of the key challenges faced by AFM researchers is to calibrate an AFM system to interpret a lateral force signal as a quantifiable force. In this study, five rectangular cantilevers were used to quantitatively compare three different lateral force calibration methods to demonstrate the legitimacy and to establish confidence in the quantitative integrity of the proposed methods. The Flat-Wedge method is based on a variation of the lateral output on a surface with flat and changing slopes, the Multi-Load Pivot method is based on taking pivot measurements at several locations along the cantilever length, and the Lateral AFM Thermal-Sader method is based on determining the optical lever sensitivity from the thermal noise spectrum of the first torsional mode with a known torsional spring constant from the Sader method. The results of the calibration using the Flat-Wedge and Multi-Load Pivot methods were found to be consistent within experimental uncertainties, and the experimental uncertainties of the two methods were found to be less than 15%. However, the lateral force sensitivity determined by the Lateral AFM Thermal-Sader method was found to be 8-29% smaller than those obtained from the other two methods. This discrepancy decreased to 3-19% when the torsional mode correction factor for an ideal cantilever was used, which suggests that the torsional mode correction should be taken into account to establish confidence in Lateral AFM Thermal-Sader method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2015.10.028DOI Listing

Publication Analysis

Top Keywords

lateral force
16
method based
12
lateral afm
12
afm thermal-sader
12
thermal-sader method
12
torsional mode
12
lateral
8
force
8
force calibration
8
calibration methods
8

Similar Publications

Balance is crucial for various athletic tasks, and accurately assessing balance ability among elite athletes using simple and accessible measurement methods is a significant challenge in sports science. A common approach to balance assessment involves recording center of pressure (CoP) displacements using force platforms, with various indicators proposed to distinguish subtle balance differences. However, these indicators have not reached a consensus, and it remains unclear whether these analyses alone can fully explain the complex interactions of postural control.

View Article and Find Full Text PDF

Despite the high incidence of knee injuries reported in non-professional sports, the implementation of specific training programmes aimed at mitigating the kinematic and kinetic factors associated with these injuries remains limited. To determine the effects of a tailored exercise programme on kinematic and kinetic variables during side-cutting activities. Fifty-seven physically active participants were randomised into control group (CG; n: 28) that received no intervention, and an experimental group (EG; n: 29), that performed an individualised exercise programme that included a combination of strength, neuromuscular, proprioceptive, eccentric training and whole-body vibration (WBV) exercises.

View Article and Find Full Text PDF

Musculoskeletal modeling based on inverse dynamics provides a cost-effective non-invasive means for calculating intersegmental joint reaction forces and moments, solely relying on kinematic data, easily obtained from smart wearables. On the other hand, the accuracy and precision of such models strongly hinge upon the selected scaling methodology tailored to subject-specific data. This study investigates the impact of upper body mass distribution on internal and external kinetics computed using a comprehensive musculoskeletal model during level walking in both normal weight and obese individuals.

View Article and Find Full Text PDF

The highest sheet symmetry form of graphyne, with one triple bond between each neighboring hexagon in graphene, irreversibly transforms exothermically at ambient pressure and low temperatures into a nongraphitic, planar-sheet, zero-bandgap phase consisting of intrasheet-bonded sp carbons. The synthesis of this sp carbon phase is demonstrated, and other carbon phases are described for possible future synthesis from graphyne without breaking graphyne bonds. While measurements and theory indicate that the reacting graphyne becomes nonplanar because of sheet wrinkling produced by dimensional mismatch between reacted and nonreacted sheet regions, sheet planarity is regained when the reaction is complete.

View Article and Find Full Text PDF

How well do empirical molecular mechanics force fields model the cholesterol condensing effect?

J Chem Phys

January 2025

School of Chemistry, University of Southampton, Highfield, Southampton SO17 1BJ, United Kingdom.

Membrane properties are determined in part by lipid composition, and cholesterol plays a large role in determining these properties. Cellular membranes show a diverse range of cholesterol compositions, the effects of which include alterations to cellular biomechanics, lipid raft formation, membrane fusion, signaling pathways, metabolism, pharmaceutical therapeutic efficacy, and disease onset. In addition, cholesterol plays an important role in non-cellular membranes, with its concentration in the skin lipid matrix being implicated in several skin diseases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!