Purpose: The purpose of this paper was to observe and compare long-term curative effects and complications of FIGO stage IIB cervical cancer patients (n = 232) treated with high-dose-rate (HDR) californium ((252)Cf) neutron or cobalt ((60)Co) photon intracavitary brachytherapy (ICBT) combined with external-beam radiotherapy (EBRT).
Material And Methods: The EBRT dose to the small pelvis was 50 Gy in both groups. The brachytherapy component of (252)Cf or (60)Co was added in the 3(rd) week of EBRT, 5 fractions were performed once per week resulting in a total ICBT dose of 40 Gy/Gyeq (point A).
Results: Overall survival (OS) at 5, 10 and 15 years was 63.6%, 50.4% and 38.8% in the (252)Cf group and 62.2%, 50.5%, 39.9%, in the (60)Co group, respectively (p = 0.74). The percentage of tumour recurrence was statistically significantly lower in the (252)Cf group with 7.4% versus 17.1% in the (60)Co group (p = 0.02). Second primary cancers have developed similarly 9.1% and 8.1% cases for (252)Cf and (60)Co groups, respectively.
Conclusions: Our long-term retrospective study comparing (252)Cf and (60)Co isotopes with brachytherapy in combined treatment of FIGO IIB stage cervix carcinoma patients shows, that overall survival in the both groups are similar. However, the recurrence of tumour was significantly lower in the (252)Cf group. The incidence of second primary cancers was similar in both groups.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4663213 | PMC |
http://dx.doi.org/10.5114/jcb.2015.55117 | DOI Listing |
This paper provides a comprehensive study of neutron calibration methodologies, specifically highlighting the capabilities for n-γ discrimination in diamond and EJ-309, and stilbene scintillation detectors. The calibration process detailed in this study includes pulse height analysis and pulse shape discrimination, relying on the analysis of charge deposition resulting from both γ and neutron interactions. Utilizing 60Co and 252Cf radiation sources, the energy spectra of these sources are obtained.
View Article and Find Full Text PDFAppl Radiat Isot
February 2024
Faculty of Science and Engineering, Waseda University, Japan.
High sensitivity and high resolution is desired in such technologies as neutron radiography. However, the contamination of gamma photons in neutron images decreases the accuracy of neutron radiography. To solve this problem, we developed an event-by-event based neutron imaging system that can selectively detect neutrons.
View Article and Find Full Text PDFSensors (Basel)
May 2022
Nuclear Power Institute of China, Chengdu 610213, China.
This study presents a real-time monitoring technique for radioactive substances that meets safety management needs. We studied the accumulation characteristics of radiation response signals of monolithic active pixel sensors (MAPSs) based on their response and discrimination ability to gamma (γ) photon or neutron radiation. The radiation status of the radioactive substances was determined by monitoring the accumulation data of radiation responses.
View Article and Find Full Text PDFHealth Phys
February 2022
NASA Ames Research Center, Moffett Field, CA.
The objective of this paper is to evaluate the accuracy of the NASA BioSentinel Pixel Dosimeter (BPD) using gamma-ray and neutron sources in a standard calibration lab. The dosimeter tested here is the ground-based version of the BPD that will be onboard the BioSentinel mission. The BPD was exposed to radiation from 60Co, 137Cs, and 252Cf at selected distances (dose rates) at the Lawrence Livermore National Laboratory (LLNL) Radiation Calibration Laboratory (RCL), and the results were compared with NIST traceable benchmark values.
View Article and Find Full Text PDFBrachytherapy
March 2019
Department of Radiation Oncology, Warren Alpert Medical School of Brown University, Providence, RI.
Purpose: Second primary malignancies (SPMs) may occur in organs after radiotherapy (RT). This study aimed to determine the rate and distribution of SPMs for photon- or neutron-emitting radiotherapy sources for patients treated for primary endometrial cancer.
Methods And Materials: The cohort comprised 426 patients with 5334 patient-years of observation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!