A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Concentric Tube Robots as Steerable Needles: Achieving Follow-the-Leader Deployment. | LitMetric

Concentric Tube Robots as Steerable Needles: Achieving Follow-the-Leader Deployment.

IEEE Trans Robot

Department of Mechanical Engineering, Vanderbilt University, Nashville, TN 37235 USA.

Published: April 2015

Concentric tube robots can enable new clinical interventions if they are able to pass through soft tissue, deploy along desired paths through open cavities, or travel along winding lumens. These behaviors require the robot to deploy in such a way that the curved shape of its shaft remains unchanged as the tip progresses forward (i.e., "follow-the-leader" deployment). Follow-the-leader deployment is challenging for concentric tube robots due to elastic (and particularly torsional) coupling between the tubes that form the robot. However, as we show in this paper, follow-the-leader deployment is possible, provided that tube precurvatures and deployment sequences are appropriately selected. We begin by defining follow-the-leader deployment and providing conditions that must be satisfied for a concentric tube robot to achieve it. We then examine several useful special cases of follow-the-leader deployment, showing that both circular and helical precurvatures can be employed, and provide an experimental illustration of the helical case. We also explore approximate follow-the-leader behavior and provide a metric for the similarity of a general deployment to a follow-the-leader deployment. Finally, we consider access to the hippocampus in the brain to treat epilepsy, as a motivating clinical example for follow-the-leader deployment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4662566PMC
http://dx.doi.org/10.1109/TRO.2015.2394331DOI Listing

Publication Analysis

Top Keywords

follow-the-leader deployment
28
concentric tube
16
tube robots
12
deployment
10
follow-the-leader
8
deployment follow-the-leader
8
concentric
4
robots steerable
4
steerable needles
4
needles achieving
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!