An In Vitro Hemodynamic Flow System to Study the Effects of Quantified Shear Stresses on Endothelial Cells.

Cardiovasc Eng Technol

Department of Anatomy and Cell Biology, University of Western Ontario, London, ON, N6A 5B8, Canada.

Published: March 2016

Numerous in vitro systems have previously been developed and employed for studying the effects of hemodynamics on endothelial cell (EC) dysfunction. In the majority of that work, accurate flow quantification (e.g., uniformity of the flow over the ECs) remains elusive and wall shear stress (WSS) quantifications are determined using theoretical relationships (without considering the flow channel aspect ratio effects). In addition, those relationships are not applicable to flows other than steady laminar cases. The present work discusses the development of a novel hemodynamic flow system for studying the effects of various well-quantified flow regimes over ECs. The current work presents a novel hemodynamic flow system applying the concept of a parallel plate flow chamber (PPFC) with live microscopy access for studying the effects of quantified WSS on ECs. A range of steady laminar, pulsatile (carotid wave form) and low-Reynolds number turbulent WSSs were quantified through velocity field measurements by a laser Doppler velocimetry (LDV) system, to validate the functionality of the current hemodynamic flow system. Uniformity of the flow across the channel width can be analyzed with the current system (e.g., the flow was uniform across about 65-75% of the channel width for the steady cases). The WSS obtained from the experiments had higher values in almost all of the cases when compared to the most commonly-used theoretical solution (9% < error < 16%), whereas another relationship, which considers the channel dimensions, had better agreement with the experimental results (1% < error < 8%). Additionally, the latter relationship predicted the uniform flow region in the PPFC with an average difference of <5% when compared to the experimental results. The experimental data also showed that the WSS at various locations (D, E and F) at the test section differed by less than 4% for the laminar cases representing a fully developed flow. WSS was also determined for a low-Re (Re = 2750) turbulent flow using (1) the Reynolds shears stress and (2) the time-averaged velocity profile gradient at the wall, with a good agreement (differences <16%) between the two where the first method returned a higher value than the second. Porcine aortic endothelial cell (PAEC) viability in the system and morphological cell response to laminar WSS of about 11 dyne/cm(2), were observed. These results provide performance validation of this novel in vitro system with many improved features compared to previous similar prototypes for investigation of flow effects on ECs. The integration of the LDV technique in the current study and the comparison of the results with those from theory revealed that great care must be taken when using PPFCs since the commonly used theoretical relation for laminar steady flows is unable to predict the flow uniformity (which may introduce significant statistical bias in biological studies) and the predicted WSS was subjected to greater error when compared to a more comprehensive equation presented in the current work. Moreover, application of the LDV technique in the current system is essential for studies of more complex cases, such as disturbed flows, where the WSS cannot be predicted using theoretical or numerical modelling methods.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13239-015-0250-xDOI Listing

Publication Analysis

Top Keywords

hemodynamic flow
16
flow system
16
studying effects
12
flow
10
effects quantified
8
uniformity flow
8
steady laminar
8
novel hemodynamic
8
channel width
8
system
6

Similar Publications

Haemodynamic and hyperaemic effects of adenosine in patients with atrial fibrillation undergoing quantitative myocardial perfusion cardiovascular magnetic resonance.

Eur Heart J Imaging Methods Pract

July 2024

Department of Cardiovascular Sciences, University of Leicester and the National Institute for Health Research Leicester Biomedical Research Centre, Glenfield Hospital, Leicester LE3 9QP, UK.

Aims: Patients with atrial fibrillation (AF) are thought to have an attenuated response to adenosine during vasodilator stress testing. We sought to investigate the haemodynamic and hyperaemic effects of adenosine in patients with AF undergoing adenosine-stress cardiovascular magnetic resonance (CMR) assessment.

Methods And Results: We retrospectively examined 318 patients referred for clinical adenosine-stress CMR (AF = 158, sinus rhythm [SR] = 160).

View Article and Find Full Text PDF

Effects of missing data imputation methods on univariate blood pressure time series data analysis and forecasting with ARIMA and LSTM.

BMC Med Res Methodol

December 2024

School of Mathematical & Statistical Sciences, University of Texas Rio Grande Valley, One West University Boulevard, Brownsville, TX, 78520, USA.

Background: Missing observations within the univariate time series are common in real-life and cause analytical problems in the flow of the analysis. Imputation of missing values is an inevitable step in every incomplete univariate time series. Most of the existing studies focus on comparing the distributions of imputed data.

View Article and Find Full Text PDF

As the number of cerebral aneurysms treated with flow diverters continues to increase, it is important to understand what factors influence not only thrombus formation within the aneurysm cavity but also fibrin accumulation across the device and its associated disruption and blockage of the inflow stream. Both processes contribute to the eventual occlusion of the aneurysm or its continued patency and incomplete occlusion which may require future re-treatment. To investigate fibrin accumulation on flow diverters placed across the neck of cerebral aneurysms, a previously developed computational model that couples flow and fibrin dynamics is used in combination with experimental in vitro models of cerebral aneurysms treated with flow diverters.

View Article and Find Full Text PDF

Introduction: Many studies have shown that coronary artery bypass grafting (CABG) increases the survival rate of patients, but the effect of bypass grafting on cardiac function is still a matter of debate.

Objective: The objective of our study was to determine: a. To what extent can the change in coronary sinus flow be used as an intraoperative criterion for the assessment of adequate revascularization.

View Article and Find Full Text PDF

The pericardium plays an important role in mechanical interactions between the right (RV) and left (LV) ventricles, referred to as ventricular interdependence. However, the exact mechanisms of its supportive role remain unknown. The present study aimed to evaluate specifically ventricular interdependence in a model of isolated biventricular working heart of large mammal, which is in absence of neurohormonal influence or series interactions, and to evaluate the impacts of intact pericardium on this phenomenon.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!