Objective: To develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of desloratadine and its metabolite 3-OH desloratadine in human plasma.
Methods: 24 healthy male volunteers received a single oral dose of 5 mg desloratadine tablets in a randomized crossover bioequivalence study with two preparations of tablets. Serial plasma samples were taken and analyzed by the LC-MS/MS method. The pharmacokinetic parameters of the two preparations were calculated and compared statistically to evaluate their bioequivalence using Winnonlin 6. 3.
Results: The calibration curves of desloratadine and 3-OH desloratadine were both linear over the concentration range of 0. 050-6. 0 ng/mL, with intra-batch and inter-batch relative standard deviations less than 15%. The 90% confidence intervals (CIs) of peak concentration (Cmax) area under the curve (AUC)0t and AUC0-∞ of desloratadine and 3-OH desloratadine all resided within the bioequivalence limit 80%-125%. No significant difference in peak time (Tmax) was demonstrated between the two preparations.
Conclusion: The LC-MS/MS method can be used for simultaneous determination of desloratadine and 3-OH desloratadine in human plasma, which has been successfully applied-to a bioequivalence study.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!