Reacting With or Without Detecting.

Motor Control

Research Institute MOVE, Department of Human Movement Sciences, Vrije Universiteit Amsterdam, Netherlands.

Published: April 2016

We begin our response by clarifying the concept of detection, and explaining why this is needed for initiating, but not for adjusting a movement. We present a simulation to illustrate this difference. Several commentators referred to studies with results that might seem in conflict with our proposal that movement adjustments have short latencies because there is no need to detect anything. In the last part of our response, we discuss how we interpret these studies as being in line with our proposal.

Download full-text PDF

Source
http://dx.doi.org/10.1123/mc.2015-0081DOI Listing

Publication Analysis

Top Keywords

reacting detecting
4
detecting response
4
response clarifying
4
clarifying concept
4
concept detection
4
detection explaining
4
explaining needed
4
needed initiating
4
initiating adjusting
4
adjusting movement
4

Similar Publications

Heterogeneity in Fluorescence-Stained Sperm Membrane Patterns and Their Dynamic Changes Towards Fertilization in Mice.

Front Biosci (Landmark Ed)

January 2025

Graduate School of Life and Environmental Sciences, Integrated Graduate School of Medicine, Engineering, and Agricultural Sciences, University of Yamanashi, 400-8510 Kofu, Japan.

Background: Sperm represent a heterogeneous population crucial for male reproductive success. Additionally, sperm undergo dynamic changes during maturation and capacitation. Despite these well-established processes, the complex nature of sperm heterogeneity and membrane dynamics remains elusive.

View Article and Find Full Text PDF

Textronic Sensors of Hazardous Gaseous Substances.

Materials (Basel)

January 2025

Faculty of Electrical, Electronic, Computer and Control Engineering, Lodz University of Technology, 18. Stefanowskiego Str., 90-924 Lodz, Poland.

Toxic materials are a threat in workplaces and the environment, as well as households. In them, gaseous substances are included, especially ones without any colour or fragrance, due to their non-detectability with the human senses. In this article, an attempt was made to find a solution for its detection in various conditions with the use of intelligent textiles.

View Article and Find Full Text PDF

Mechanistic Insights into CO Adsorption of LiSiO at High Temperature.

Materials (Basel)

January 2025

Hunan Key Laboratory of Applied Environmental Photocatalysis, School of Materials and Environmental Engineering, Changsha University, Changsha 410022, China.

The development of materials with high adsorption capacity for capturing CO from industrial exhaust gases has proceeded rapidly in recent years. LiSiO has attracted attention due to its low cost, high capture capacity, and good cycling stability for direct high-temperature CO capture. Thus far, the CO adsorption mechanism of LiSiO is poorly understood, and detailed phase transformations during the CO adsorption process are missing.

View Article and Find Full Text PDF

Microbial contamination is an important factor threatening the safety of Chinese medicine preparations, and microfluidic detection methods have demonstrated excellent advantages in the application of rapid bacterial detection. In our study, a novel optical biosensor was developed for the rapid and sensitive detection of in traditional Chinese medicine on a microfluidic chip. Immune gold@platinum nanocatalysts (Au@PtNCs) were utilized for specific bacterial labeling, while magnetic nano-beads (MNBs) with a novel high-gradient magnetic field were employed for the specific capture of bacteria.

View Article and Find Full Text PDF

The reaction mechanisms of ethylene oxide and propylene oxide with food Simulants: Based on experiments and computational analysis.

Food Res Int

February 2025

College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China; Engineering Research Center of Food Thermal-Processing Technology, Shanghai Ocean University, Shanghai 201306, China. Electronic address:

Ethylene oxide (EO) and propylene oxide (PO) are widely used as sterilizing agents in the food industry. However, their residues in food packaging can migrate into food and react with it, affecting the accuracy of residue detection in food. This study aims to explore the reaction mechanisms between EO and PO and aqueous food simulants using both experimental and computational methods.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!