Purpose: The goals of this retrospective study were to evaluate the accuracy of core needle biopsy (CNB) for the diagnosis of osteosarcoma and to identify criteria that may predict failed CNB.
Materials And Methods: From 2002 to 2012, 73patients with a total of 73osteosarcomas underwent CNB. Patients demographics and procedure details were recorded, including tumor size, tumor characteristics (hemorrhagic or not, lytic, sclerotic [>50% bone condensation], or mixed), the type of anesthesia, the number of tissue samples, the size of the biopsy needle and pathology report. Procedures were analyzed in terms of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV).
Results: A diagnosis was not made in 5/73patients (6.8%) with an overall sensitivity of 93.1%, a specificity of 100%, a PPV of 100% and a NPV of 99.9%. No complications due to CNB were observed. No criteria were identified as predictors of CNB failure.
Conclusion: Even in the presence of sclerotic tumors, CNB should be the first line diagnostic test for suspected osteosarcomas, pending performance by a well-trained radiologist and reading by a specialized pathologist.
Level Of Evidence: IV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.diii.2015.09.013 | DOI Listing |
Adv Neonatal Care
January 2025
Author Affiliations: Neonatal Intensive Care Unit, Seattle Children's Hospital, Seattle, WA (Mrs LaBella, Ms Kelly, Mrs Carlin, and Dr Walsh); and Seattle Children's Research Institute, Seattle, WA (Mrs Carlin and Dr Walsh).
Background: Finding an accurate and simple method of thermometry in the neonatal intensive care unit is important. The temporal artery thermometer (TAT) has been recommended for all ages by the manufacturer; however, there is insufficient evidence for the use of TAT in infants, especially to detect hypothermia.
Purpose: To assess the accuracy of the TAT in hypothermic neonates in comparison to a rectal thermometer.
Acta Radiol
January 2025
Department of Medical Imaging, Dalin Tzu-Chi Hospital, Chiayi, Taiwan.
Background: The wide variability in thresholds on computed tomography (CT) perfusion parametric maps has led to controversy in the stroke imaging community about the most accurate measurement of core infarction.
Purpose: To investigate the feasibility of using U-Net to perform infarct core segmentation in CT perfusion imaging.
Material And Methods: CT perfusion parametric maps were the input of U-Net, while the ground truth segmentation was determined based on diffusion-weighted imaging (DWI).
Front Psychiatry
January 2025
Department of Infection Management, Wuxi No.2 People's Hospital (Jiangnan University Medical Center), Wuxi, China.
Objective: In this study, we examine the network structure of posttraumatic stress disorder (PTSD), including core symptoms and strong edges in patients undergoing chemotherapy for colorectal cancer in China, and lay the groundwork for targeted psychological interventions for these patients.
Methods: This study included 360 colorectal cancer patients receiving chemotherapy at a third-class hospital in Wuxi, China, from November 2023 to June 2024. The severity of each item of PTSD was assessed using the DSM-5 Checklist (PCL-5).
Front Artif Intell
January 2025
College of Computer and Control Engineering, Northeast Forestry University, Harbin, China.
Introduction: In clinical, the echocardiogram is the most widely used for diagnosing heart diseases. Different heart diseases are diagnosed based on different views of the echocardiogram images, so efficient echocardiogram view classification can help cardiologists diagnose heart disease rapidly. Echocardiogram view classification is mainly divided into supervised and semi-supervised methods.
View Article and Find Full Text PDFBMC Cancer
January 2025
Department of Urology, Fujian Union Hospital, Fujian Medical University, Fuzhou, 350001, Fujian Province, China.
Background: Prostate cancer (PCa) is definitively diagnosed by systematic prostate biopsy (SBx) with 13 cores. This method, however, can increase the risk of urinary retention, infection and bleeding due to the excessive number of biopsy cores.
Methods: We retrospectively analyzed 622 patients who underwent SBx with prostate multiparametric MRI (mpMRI) from two centers between January 2014 to June 2022.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!