Objectives: Aortic valve replacement (AVR) with sutureless bioprostheses has become an alternative to conventional AVR for patients with intermediate to high operative risk. However, this technique is associated with an increased risk of postoperative conduction disorders.

Methods: We analysed 258 patients who underwent AVR with the Perceval prosthesis from July 2010 to September 2014 at our centre. Electrocardiography were obtained at baseline to record preoperatively the presence of conduction disorders. Preoperative risk factors, intraoperative procedures and complications (61 variables) were compared between patients with permanent pacemaker (PPM group) and without (no-PPM group) need for postoperative PPM implantation.

Results: One hundred and sixty-nine patients underwent isolated AVR with the Perceval bioprosthesis, 89 patients had associated surgery and 23 patients underwent redo operations. The mean age was 77.7 ± 5 years, 139 patients were female (46%) and the mean logistic EuroSCORE was 13.2 ± 11%. At baseline, 8 patients had already an implanted pacemaker. Postoperatively, 27 patients (10.5%) required new PPM implantation due to complete atrioventricular block. On univariate analysis, age (PPM vs no-PPM group: 80 ± 5 vs 77 ± 5 years, P = 0.009) and preoperative presence of right bundle branch block (RBBB) [overall n = 20 (7.8%); PPM vs no-PPM group: 9 vs 11 (33 vs 4.8%); P < 0.001] were identified as independent predictors of postoperative conduction disorders, but only pre-existing RBBB persisted on multivariate analysis (odds ratio 11.3-C-statistic 0.74, error estimate 0.064, confidence interval 0.672-0.801; P = 0.0002). Among patients undergoing sutureless AVR, the rate of PPM implantation was high.

Conclusions: The analysis of the data collected made it possible to identify preoperatively a subset of patients undergoing sutureless AVR at higher risk of postoperative atrioventricular block. Additional surgical precautions should be implemented to prevent the occurrence of conduction disorders after sutureless AVR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4986555PMC
http://dx.doi.org/10.1093/icvts/ivv330DOI Listing

Publication Analysis

Top Keywords

patients underwent
12
conduction disorders
12
no-ppm group
12
sutureless avr
12
patients
11
aortic valve
8
valve replacement
8
perceval bioprosthesis
8
risk postoperative
8
postoperative conduction
8

Similar Publications

Unconfirmed penicillin allergies over time lead to poor health outcomes and increased health-care cost. Health disparities (HD) can create barriers in optimizing penicillin allergy care. The objective was to characterize HDs in our primary care-led amoxicillin challenge (PLAC) delabeling pathway within a universal coverage health care system.

View Article and Find Full Text PDF

Application of additive manufacturing TaBw01 porous tantalum rod in ARCO stage II osteonecrosis of the femoral head.

J Orthop Surg Res

December 2024

Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.

Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).

Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.

View Article and Find Full Text PDF

Purpose: To assess and compare the diagnostic efficiency of histogram analysis of monochromatic and iodine images derived from spectral CT in predicting Ki-67 expression in gastric gastrointestinal stromal tumors (gGIST).

Methods: Sixty-five patients with gGIST who underwent spectral CT were divided into a low-level Ki-67 expression group (LEG, Ki-67 < 10%, n = 33) and a high-level Ki-67 expression group (HEG, Ki-67 ≥ 10%, n = 32). Conventional CT features were extracted and compared.

View Article and Find Full Text PDF

Background: Takayasu arteritis is a large-vessel vasculitis, in addition to giant cell arteritis. Various post-operative complications associated with the cardiac macrovasculature have been reported. Detachment of the prosthetic valve, pseudoaneurysm formation, and dilatation of the aortic root are well-known post-operative complications associated with vasculitis syndromes, including Takayasu arteritis.

View Article and Find Full Text PDF

Objective: This study aims to explore the predictive value of endplate morphology and pedicle screw bone quality score on screw loosening after single-level lumbar spinal fusion surgery.

Methods: A retrospective analysis was conducted on the clinical data of 207 patients who underwent single-level lumbar spinal fusion (34 in the screw loosening group and 173 in the non-screw loosening group). Univariate analysis and binary logistic regression model analysis were performed using SPSS 27.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!