Aims: The aim of this study was to determine the long-term effects and determinants of success of cardiac pacing in patients affected by reflex syncope enrolled in the Syncope Unit Project 2 (SUP 2) study. Initial results have validated the effectiveness of a standardized guideline-based algorithm which can be used in clinical practice in order to select suitable candidates for cardiac pacing.
Methods And Results: In this prospective, multicentre, observational study, patients aged >40 years, affected by severe unpredictable recurrent reflex syncope, underwent carotid sinus massage (CSM), followed by tilt testing (TT) if CSM was negative, followed by implantation of an implantable loop recorder (ILR) if TT was negative. Those who had an asystolic response to one of these tests received a dual-chamber pacemaker. Of 281 patients who met the inclusion criteria, 137 (49%) received a pacemaker and were followed up for a mean of 26 ± 11 months: syncope recurred in 25 (18%) of them. At 3 years, the actuarial syncope recurrence rate was 20% [95% confidence interval (CI) 12-30] and was significantly lower than in 142 patients who did not receive a pacemaker and were observed by means of an ILR [43% (95% CI 29-57), P = 0.01]. The 3-year recurrence rate was not different among 78 CSM+, 38 TT+, and 21 ILR+ patients, whereas it was lower in 20 patients with negative TT [5% (95% CI 0-15)] than in 61 patients with positive TT [24% (95% CI 10-38)].
Conclusion: The benefit of cardiac pacing is maintained at 3 years, irrespective of the index diagnostic test, and is maximum in patients with negative TT.
Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01509534.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/euv343 | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Electrophysiology and Cardiac Pacing Unit, San Giuliano Hospital, Giugliano in Campania, Italy.
We present the case of a 64-year-old man who, during the implantation of an active-fixation leadless pacemaker (LP, Aveir VR, Abbott, USA), underwent several external defibrillation shocks up to 240 Joules, due to symptomatic sustained supraventricular tachycardia at 160 bpm. The shocks, delivered both before and after the screwing of the device in the low interventricular septum, did not cause any technical damage to the device, and no complications were observed. The device was then deployed successfully.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Service de rythmologie cardiaque, Hôpital Cardiologique Louis Pradel, Hospices Civils de Lyon, Lyon, France.
Background: Temporary transvenous pacing (TTP) is a common procedure, predominantly performed in the catheterization laboratory (cath lab) because of presumed lower complication rate. This study aims to evaluate the efficacy and safety of TTP placement in the ICU compared to TTP placement in the cath lab.
Methods: This retrospective, real-life study included all patients requiring TTP in a tertiary care ICU between 2019 and 2022.
Ann Thorac Surg Short Rep
December 2024
Department of Pediatric Cardiothoracic Surgery, Children's Hospital of New Orleans, New Orleans, Louisiana.
An infant with DiGeorge syndrome, multiple comorbidities, and truncus arteriosus type II underwent repair complicated by heart block necessitating placement of a dual-chamber bipolar pacing system with right ventricular leads and subsequent resynchronization with placement of left ventricular apical pacing leads. Resynchronization therapy improved QRS duration from 180 ms to 100 ms and ejection fraction from 25% to 54% over the course of 4 weeks with gradual return to normal function and eventual discharge.
View Article and Find Full Text PDFZhonghua Nei Ke Za Zhi
January 2025
Department of Pacing Electrophysiology, the First Affiliated Hospital of Xinjiang Medical University, Urumqi830000, China.
The aim of this study was to assess the frailty status of patients with heart failure undergoing CRT-D and then explore the predictive value of frailty for all-cause mortality and heart failure-related readmissions in these patients. We retrospectively included 374 patients with chronic heart failure who underwent CRT-D treatment at the First Affiliated Hospital of Xinjiang Medical University between June 2020 and June 2024. Based on the Tilburg Debilitation Assessment Scale, 175 patients (46.
View Article and Find Full Text PDFExpert Rev Med Devices
January 2025
Cardiology Unit, "Card. G. Panico" Hospital, Tricase (Le), Italy.
Introduction: In patients with symptomatic, refractory atrial fibrillation the ablate and pace (A&P) strategy (pacemaker implantation followed by atrio-ventricular junction ablation (AVJA)) is superior to medical therapy in improving quality of life and prognosis. Despite its well-proven benefits, this invasive therapeutic option is still underutilized in clinical practice. The choice of pacing modality (right ventricular pacing, biventricular pacing, BVP, or conduction system pacing, CSP) is crucial and can have significant clinical implications.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!