Purpose: The aim of this study was to compare inverse planning-simulated annealing (IPSA) with geometric optimization (GO) in high-dose-rate (HDR) prostate brachytherapy, to assess variations in dosimetric indices associated to catheter displacement.
Methods And Materials: We retrospectively studied the dosimetric effect of catheter displacement in 20 patients treated with HDR prostate brachytherapy with salvage intention. The catheter loadings, with optimized dwell positions, from the first fraction were transferred to the catheter positions in the second fraction.
Results: Median catheter displacement was 8.7 ± 3.3 mm (range, 2.7 ± 1.1 mm-14.7 ± 1.7 mm). D90% median variations for IPSA and GO were -10% with a maximum of -59%, and -29% with a maximum of -63%, respectively. V100% median variation was -11% with a maximum of -37% for IPSA, and -20% with a maximum of -37% for GO. V150/V100 implant median variations were 15% and 9% for IPSA and GO with maximum values of 65% and 47%, respectively (p < 0.05). No significant differences were observed for V200/V100 indices, nor were any significant differences found for organs at risk. Correlation between mean catheter displacement and dosimetric indices was found only in the planning target volume D90% and V100%; linear regression slopes were -2.0% per mm and -2.6% per mm for IPSA vs. -2.4% per mm and -3.5% per mm for GO.
Conclusions: IPSA does not present any additional risk compared with GO in HDR prostate brachytherapy when catheter uncertainties are taken into account. Moreover, IPSA optimization preserves planning target volume coverage better than GO, suggesting that it may be superior when catheter displacement is considered.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.brachy.2015.10.003 | DOI Listing |
J Clin Nurs
January 2025
Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, China.
Aims And Objectives: This study aimed to investigate the impact of sleep position preferences (SPP) on sleep quality, comfort and catheter care quality in patients after endoscopic nasobiliary drainage (ENBD).
Design: This was an observational prospective study.
Methods: This study included 167 participants with common bile duct stones (CBDS) who underwent ENBD from the gallstone ward of a hospital as a convenience sample.
Catheter Cardiovasc Interv
January 2025
The Christ Hospital Heart and Vascular Institute, Cincinnati, Ohio, USA.
One of the major issues encountered in patients undergoing evaluation for Transcatheter mitral valve replacement (TMVR) is the risk of Left ventricular outflow tract (LVOT) obstruction. LVOT obstruction is a catastrophic complication of TMVR, the result of displacement of the anterior mitral valve leaflet (AML) toward the interventricular septum. Several strategies to mitigate the risk of LVOT obstruction have been described and include percutaneous laceration of the anterior mitral leaflet (LAMPOON), alcohol septal ablation, trans-atrial leaflet modification (SITRAL) and Balloon Assisted Translocation of Mitral Anterior leaflet to prevent LVOT obstruction (BATMAN).
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Service de rythmologie cardiaque, Hôpital Cardiologique Louis Pradel, Hospices Civils de Lyon, Lyon, France.
Background: Temporary transvenous pacing (TTP) is a common procedure, predominantly performed in the catheterization laboratory (cath lab) because of presumed lower complication rate. This study aims to evaluate the efficacy and safety of TTP placement in the ICU compared to TTP placement in the cath lab.
Methods: This retrospective, real-life study included all patients requiring TTP in a tertiary care ICU between 2019 and 2022.
J Cardiothorac Surg
January 2025
Department of Cardiovascular Surgery of The First Affiliated Hospital, Zhejiang University School of Medicine, 79 Qingchun Road, Hangzhou, Zhejiang, 310000, China.
Interventional occlusion of Patent ductus arteriosus (PDA) is generally efficacious and complications such as delayed occluder displacement are infrequent. Herein, we report a case of 24-year-old female with a history of unsuccessful PDA closures, who subsequently experienced delayed occluder displacement into the left main pulmonary artery. Despite numerous unsuccessful catheter-based interventions, thoracic endovascular aortic repair (TEVAR) was successfully executed.
View Article and Find Full Text PDFCureus
December 2024
Vascular Surgery, Centro Médico Nacional 20 de Noviembre, Mexico City, MEX.
This case report evaluates current diagnostic and treatment approaches for intrapelvic acetabular migration, focusing on the rare but serious complication of acute limb ischemia following hip arthroplasty. A 67-year-old female with a history of total hip arthroplasty 10 years ago presented with acute limb ischemia after experiencing a traumatic event 72 hours prior, which had caused displacement of her hip prosthesis. Notably, she had a history of a traumatic event two years earlier for which she had been advised to undergo surgical correction, which she had refused.