To meet the requirements of riser safety monitoring in offshore oil fields, a new Fiber Bragg Grating (FBG)-based bundle-structure riser stress monitoring sensor has been developed. In cooperation with many departments, a 49-day marine test in water depths of 1365 m and 1252 m was completed on the "HYSY-981" ocean oil drilling platform. No welding and pasting were used when the sensor was installed on risers. Therefore, the installation is convenient, reliable and harmless to risers. The continuous, reasonable, time-consistent data obtained indicates that the sensor worked normally under water. In all detailed working conditions, the test results show that the sensor can do well in reflecting stresses and bending moments both in and in magnitude. The measured maximum stress is 132.7 MPa, which is below the allowable stress. In drilling and testing conditions, the average riser stress was 86.6 MPa, which is within the range of the China National Offshore Oil Corporation (CNOOC) mechanical simulation results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4701352PMC
http://dx.doi.org/10.3390/s151129648DOI Listing

Publication Analysis

Top Keywords

riser stress
12
bundle-structure riser
8
stress monitoring
8
monitoring sensor
8
offshore oil
8
stress
5
sensor
5
study test
4
test bundle-structure
4
riser
4

Similar Publications

The application of flexible risers has led to increased production of fluid contents in the marine industry. This paper presents the design challenges of a flexible riser subjected to internal pressure under deep-water conditions, at a water depth of 2000 m. Parametric variations with extensive dynamic analysis were carried out.

View Article and Find Full Text PDF

Purpose: Femur fractures are among the most common fractures treated surgically, representing a significant challenge for the orthopedic surgeon. Peri-implant femoral fractures (PIFFs) represent a rare complication of the surgical treatment. It is necessary to pay attention during osteosynthesis, evaluating not only the fracture site but the entire femoral skeletal structure, the characteristics of the fracture, the health comorbidities, and the risk of malunion and pseudarthrosis.

View Article and Find Full Text PDF

Purpose: Osteoporotic patients are at risk of peri-implant fractures after distal radius fixation. A unicortical screw in the proximal hole of the plate can theoretically decrease stress riser formation by eliminating the hole in the far bone cortex. This construct has been proposed in orthopedic literature to prevent peri-implant fractures but has not been tested in an osteoporotic distal radius model.

View Article and Find Full Text PDF

Introduction: This article presents a simultaneous operative technique, which allowed to successfully treat a Cuff Tear Arthropathy (CTA), instability and Levy-type III scapular spine fracture non-union with 90°-double plating, humerus-to-scapula grafting and simultaneous reverse shoulder arthroplasty.

Case Report: We present a 64year-old woman with previously known cuff arthropathy (2012/53yo). She fell in 2017 (58 years old with minor shoulder disability) before dislocating the shoulder in 2020 (60 years old) with evidence of a medial Levy-type III scapular spine fracture non-union and severe apprehension, unable to anterior elevate her arm more than 90°.

View Article and Find Full Text PDF

The industry of off-highway vehicles is one of the fields of major application of nodular cast irons, which guarantee the manufacture of complex geometries and ensure good mechanical properties. The present investigation deals with the fatigue design of off-highway axles made of EN-GJS-500-7. Typically, off-highway axles are weakened by stress risers which must be assessed against fatigue.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!