A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility of an Intraluminal Bypass Device in Low Colorectal Anastomosis: Preliminary Results in a Porcine Model. | LitMetric

Background: The Cologuard CG-100 is a novel intraluminal bypass device designed to reduce the clinical outcomes associated with low colorectal anastomotic leak. The device is inserted transanally, anchored to the colon above the anastomosis, and deployed intraluminally to cover the anastomosis from within. The purpose of this study was to evaluate the safety and performance of the device in a porcine model.

Method: Twelve pigs underwent low colorectal anastomosis with insertion of the Cologuard CG-100 device. Contrast material injection, abdominal X-ray, and histologic studies were used to evaluate sealing quality, device positioning, and tissue damage, respectively. The surgeons completed a usability and satisfaction questionnaire after completion of the procedure.

Results: Absolute sealing was observed in all 4 animals euthanized immediately after surgery. In the other 8 animals, the device was kept in situ for 10 days and then extracted. X-ray films with injection of contrast material through a designated injection tube before device removal showed that the sheath and ring were correctly placed. No leak was demonstrated. There were no device-related adverse events, and no critical histological abnormalities were noted in the bowel area that was compressed by the device. The device was found to be easy to insert, position, and extract.

Conclusion: The Cologuard CG-100 device efficiently reduced contact between fecal content and low colorectal anastomosis in a porcine model and is easily deployed and extracted. It holds promise for possible clinical use pending further studies.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1553350615617250DOI Listing

Publication Analysis

Top Keywords

low colorectal
16
colorectal anastomosis
12
cologuard cg-100
12
device
11
intraluminal bypass
8
bypass device
8
porcine model
8
cg-100 device
8
contrast material
8
anastomosis
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!