A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Characterization of Time-Resolved Laser-Induced Fluorescence from Crude Oil Samples]. | LitMetric

To evaluate the feasibility of laser induced time-resolved fluorescence technique for in-situ detection of underwater suspended oil spill, extensive investigations have been carried out with different densities of crude oil samples from six different wells of Shengli Oilfield in this work. It was found that the fluorescence emission durations of these crude oil samples were almost the same, the Gate Pulse Delay of DDG (Digital Delay Generator) in the ICCD started at 52ns and ended at 82ns with a width (FWHM) of 10 ns. It appears that the peak location and lifetime of fluorescence for different crude oil samples varied with their densities, and those with similar densities shared a similar lifespan with the closer peak locations of fluorescence. It is also observed that the peak of fluorescence remained the same location before reaching the maximum intensity, subsequently shift to longer wavelength as fluorescence attenuated from maximum intensity with a red shift among 17-30 nm varied with samples. This demonstrated that the decay rate of fluorescent components in the crude oils was different, and energy transfer between these components might exist. It is hoped that those obtained results and characteristics could be the useful information for identification of suspended spilled-oil underwater.

Download full-text PDF

Source

Publication Analysis

Top Keywords

crude oil
16
oil samples
12
fluorescence crude
8
maximum intensity
8
fluorescence
7
crude
5
oil
5
[characterization time-resolved
4
time-resolved laser-induced
4
laser-induced fluorescence
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!