High-speed intravascular photoacoustic imaging at 1.7 μm with a KTP-based OPO.

Biomed Opt Express

Key Laboratory of Space Laser Communication and Detection Technology, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China ;

Published: November 2015

Lipid deposition inside the arterial wall is a hallmark of plaque vulnerability. Based on overtone absorption of C-H bonds, intravascular photoacoustic (IVPA) catheter is a promising technology for quantifying the amount of lipid and its spatial distribution inside the arterial wall. Thus far, the clinical translation of IVPA technology is limited by its slow imaging speed due to lack of a high-pulse-energy high-repetition-rate laser source for lipid-specific first overtone excitation at 1.7 μm. Here, we demonstrate a potassium titanyl phosphate (KTP)-based optical parametric oscillator with output pulse energy up to 2 mJ at a wavelength of 1724 nm and with a repetition rate of 500 Hz. Using this laser and a ring-shape transducer, IVPA imaging at speed of 1 frame per sec was demonstrated. Performance of the IVPA imaging system's resolution, sensitivity, and specificity were characterized by carbon fiber and a lipid-mimicking phantom. The clinical utility of this technology was further evaluated ex vivo in an excised atherosclerotic human femoral artery with comparison to histology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4646562PMC
http://dx.doi.org/10.1364/BOE.6.004557DOI Listing

Publication Analysis

Top Keywords

intravascular photoacoustic
8
inside arterial
8
arterial wall
8
imaging speed
8
ivpa imaging
8
high-speed intravascular
4
imaging
4
photoacoustic imaging
4
imaging μm
4
μm ktp-based
4

Similar Publications

Geometry and local wall thickness of abdominal aortic aneurysms using intravascular ultrasound.

Comput Biol Med

December 2024

Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, 5600, The Netherlands.

Currently, abdominal aortic aneurysms (AAAs) are treated based on the diameter of the aorta, however, a more robust patient-specific marker is needed. The mean thickness of the wall is a potential indicator for AAA rupture risk, which varies significantly within and between patients. So far, regional thickness has not been used in previous rupture risk analysis studies, since it is challenging to measure in CT, MRI, and non-invasive ultrasound (US).

View Article and Find Full Text PDF

Multimodal intravascular ultrasound and photoacoustic (IVUS/PA) imaging is a promising diagnostic tool for cardiovascular diseases like atherosclerosis. IVUS/PA catheters typically require two independent transducers due to different frequency requirements, potentially increasing the catheter size. To facilitate multimodal imaging within conventional catheter dimensions, we designed, fabricated, and characterized a dual-transducer acoustic stack where a low-frequency (LF) PA receiver sits as a matching layer for the high-frequency (HF) US transducer.

View Article and Find Full Text PDF

Ultrawide-bandwidth high-resolution all-optical intravascular ultrasound using miniaturized photoacoustic transducer.

Sci Adv

June 2023

Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Institute of Medical Photonics, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China.

Conventional intravascular ultrasound (IVUS) uses piezoelectric transducers to electrically generate and receive ultrasound. However, it remains a challenge to achieve large bandwidth for high resolution without compromising imaging depth. We report an all-optical IVUS (AO-IVUS) imaging system using picosecond laser pulse-pumped carbon composite for ultrasound excitation and π-phase-shifted fiber Bragg gratings for ultrasound detection.

View Article and Find Full Text PDF

Epinephrine-induced Effects on Cerebral Microcirculation and Oxygenation Dynamics Using Multimodal Monitoring and Functional Photoacoustic Microscopy.

Anesthesiology

August 2023

Department of Anesthesiology, Duke University, North Carolina; Department of Anesthesiology and Pain Management, University of Texas Southwestern Medical Center, Dallas, Texas.

Background: The administration of epinephrine after severe refractory hypotension, shock, or cardiac arrest restores systemic blood flow and major vessel perfusion but may worsen cerebral microvascular perfusion and oxygen delivery through vasoconstriction. The authors hypothesized that epinephrine induces significant microvascular constriction in the brain, with increased severity after repetitive dosing and in the aged brain, eventually leading to tissue hypoxia.

Methods: The authors investigated the effects of intravenous epinephrine administration in healthy young and aged C57Bl/6 mice on cerebral microvascular blood flow and oxygen delivery using multimodal in vivo imaging, including functional photoacoustic microscopy, brain tissue oxygen sensing, and follow-up histologic assessment.

View Article and Find Full Text PDF

Thromboembolism in blood vessels can lead to stroke or heart attack and even sudden death unless brought under control. Sonothrombolysis enhanced by ultrasound contrast agents has shown promising outcome on effective treatment of thromboembolism. Intravascular sonothrombolysis was also reported recently with a potential for effective and safe treatment of deep thrombosis.

View Article and Find Full Text PDF