Quantifying the image quality and dose reduction of respiratory triggered 4D cone-beam computed tomography with patient-measured breathing.

Phys Med Biol

Radiation Physics Laboratory, Sydney Medical School, University of Sydney, NSW 2006, Australia. Department of Medical Physics and Radiation Engineering, The Canberra Hospital, Canberra, ACT 2605, Australia.

Published: December 2015

Respiratory triggered four dimensional cone-beam computed tomography (RT 4D CBCT) is a novel technique that uses a patient's respiratory signal to drive the image acquisition with the goal of imaging dose reduction without degrading image quality. This work investigates image quality and dose using patient-measured respiratory signals for RT 4D CBCT simulations. Studies were performed that simulate a 4D CBCT image acquisition using both the novel RT 4D CBCT technique and a conventional 4D CBCT technique. A set containing 111 free breathing lung cancer patient respiratory signal files was used to create 111 pairs of RT 4D CBCT and conventional 4D CBCT image sets from realistic simulations of a 4D CBCT system using a Rando phantom and the digital phantom, XCAT. Each of these image sets were compared to a ground truth dataset from which a mean absolute pixel difference (MAPD) metric was calculated to quantify the degradation of image quality. The number of projections used in each simulation was counted and was assumed as a surrogate for imaging dose. Based on 111 breathing traces, when comparing RT 4D CBCT with conventional 4D CBCT, the average image quality was reduced by 7.6% (Rando study) and 11.1% (XCAT study). However, the average imaging dose reduction was 53% based on needing fewer projections (617 on average) than conventional 4D CBCT (1320 projections). The simulation studies have demonstrated that the RT 4D CBCT method can potentially offer a 53% saving in imaging dose on average compared to conventional 4D CBCT in simulation studies using a wide range of patient-measured breathing traces with a minimal impact on image quality.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/60/24/9493DOI Listing

Publication Analysis

Top Keywords

image quality
24
conventional cbct
20
imaging dose
16
cbct
13
dose reduction
12
image
9
quality dose
8
respiratory triggered
8
cone-beam computed
8
computed tomography
8

Similar Publications

Periodontal diseases in Down syndrome during childhood: a scoping review.

BMC Oral Health

January 2025

Université Paris Cité, Laboratory URP 2496 Orofacial Pathologies, Imaging, and Biotherapies, Faculty of odontology, Montrouge, France.

Background: Down syndrome (DS) is a genetic condition that involves the deregulation of immune function and is characterized by a proinflammatory phenotype leading to an impaired response to infections. Periodontitis is a highly prevalent chronic inflammatory disease. It has been shown that adults and teenagers with DS are more susceptible to this disease, but a similar correlation in DS children remains elusive.

View Article and Find Full Text PDF

Purpose: To evaluate the staging performance of positron emission tomography/magnetic resonance imaging (PET/MRI) for confirmed esophageal cancer based on the TNM classification system as well as compare it to other alternative modalities (e.g., endoscopic ultrasonography (EUS), computed tomography (CT), MRI, and PET/CT) in a full head-to-head manner.

View Article and Find Full Text PDF

Both acute kidney injury and chronic kidney disease are risk factors for many outcomes of gastrointestinal bleeding (GIB). These are associated with higher mortality, longer hospitalisation, and greater need for transfusion in case of overt GIB. Our study aimed to further evaluate the role of kidney function in several clinical outcomes of GIB patients.

View Article and Find Full Text PDF

Accurate malaria diagnosis with precise identification of Plasmodium species is crucial for an effective treatment. While microscopy is still the gold standard in malaria diagnosis, it relies heavily on trained personnel. Artificial intelligence (AI) advances, particularly convolutional neural networks (CNNs), have significantly improved diagnostic capabilities and accuracy by enabling the automated analysis of medical images.

View Article and Find Full Text PDF

Humboldt squid (Dosidicus gigas) is the most abundant cephalopod in the fishing industry, and its high nutritional and organoleptic properties make it a go-to food product for consumers. Therefore, developing new processing techniques seems imperative to minimize quality deterioration and provide products with appropriate characteristics. The study aimed to determine the effect of high-pressure impregnation (HPI) pretreatment on hot air-drying kinetics and the quality of Humboldt squid slices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!