Risk Factors Involved in Central-to-Radial Arterial Pressure Gradient During Cardiac Surgery.

Anesth Analg

From the Departments of Anesthesiology and Cardiac Surgery, Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada; Coordinating Center, Montreal Heart Institute, Montreal, Quebec, Canada; and Department of Preventive and Social Medicine, Université de Montréal, Montreal, Quebec, Canada.

Published: March 2016

Background: A central-to-radial arterial pressure gradient may occur after cardiopulmonary bypass (CPB), which, in some patients, may last for a prolonged time after CPB. Whenever there is a pressure gradient, the radial artery pressure measure may underestimate a more centrally measured systemic pressure, which may result in a misguided therapeutic strategy. It is clinically important to identify the risk factors that may predict the appearance of a central-to-radial pressure gradient, because more central sites of measurements might then be considered to monitor systemic arterial pressure in high-risk patients. The objective of this study was to assess preoperative and intraoperative risk factors for central-to-radial pressure gradient.

Methods: Seventy-three patients undergoing cardiac surgery using CPB were included in this prospective observational study. A significant central-to-radial arterial pressure gradient was defined as a difference of 25 mm Hg in systolic pressure or 10 mm Hg in mean arterial pressure for a minimum of 5 minutes. Preoperative data included demographics, presence of comorbidities, and medications. Intraoperative data included type of surgery, CPB and aortic clamping time, use of inotropic drugs, and vasodilators or vasopressors agents. The diameter of the radial and femoral artery was measured before the induction of anesthesia using B-mode ultrasonography.

Results: Thirty-three patients developed a central-to-radial arterial pressure gradient (45%). Patients with a significant pressure gradient had a smaller weight (71.0 ± 16.9 vs 79.3 ± 17.3 kg, P = 0.041), a smaller height (162.0 ± 9.6 vs 166.3 ± 8.6 cm, P = 0.047), a smaller radial artery diameter (0.24 ± 0.03 vs 0.29 ± 0.05 cm, P < 0.001), and were at a higher risk as determined by the Parsonnet score (30.3 ± 24.9 vs 17.0 ± 10.9, P = 0.007). In addition, a longer aortic clamping time (85.8 ± 51.0 vs 64.2 ± 29.3 minutes, P = 0.036), mitral and complex surgery (P = 0.007 and P = 0.017, respectively), and administration of vasopressin (P = 0.039) were identified as potential independent predictors of a central-to-radial pressure gradient. By using multivariate logistic regression analysis, the following independent risk factors were identified: Parsonnet score (odds ratio [OR], 1.076; 95% confidence interval [CI], 1.027-1.127, P = 0.002), aortic clamping time >90 minutes (OR, 8.521; 95% CI, 1.917-37.870, P = 0.005), and patient height (OR, 0.933, 95% CI, 0.876-0.993, P = 0.029). The relative risk (RR) estimates remained statistically significant for the Parsonnet score and the aortic clamping time ≥90 minutes (RR, 1.010; 95% CI, 1.003-1.018, P = 0.009 and RR, 2.253; 95% CI, 1.475-3.443, P < 0.001 respectively) while showing a trend for patient height (RR, 0.974; 95% CI, 0.948-1.001, P = 0.058).

Conclusions: Central-to-radial gradients are common in cardiac surgery. The threshold for using a central site for blood pressure monitoring should be low in small, high-risk patients undergoing longer surgical interventions to avoid inappropriate administration of vasopressors and/or inotropic agents.

Download full-text PDF

Source
http://dx.doi.org/10.1213/ANE.0000000000001096DOI Listing

Publication Analysis

Top Keywords

pressure gradient
32
arterial pressure
24
risk factors
16
central-to-radial arterial
16
aortic clamping
16
clamping time
16
pressure
15
cardiac surgery
12
central-to-radial pressure
12
parsonnet score
12

Similar Publications

Myocardial work (MW) is a new echocardiographic parameter used in the assessment of cardiac energy expenditure. The aim of the current study was to evaluate changes in left ventricular MW parameters in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). One hundred and thirty five consecutive patients who underwent TAVI at one center were evaluated before and after the procedure using transthoracic echocardiography (TTE) to assess the following MW indices: global constructive work (GCW), global wasted work (GWW), global work index (GWI) and global work efficiency (GWE).

View Article and Find Full Text PDF

Exploring tazarotene, a third-generation retinoid for potential hand osteoarthritis treatment, this study presents the development and validation of an ultra-performance liquid chromatography with quadrupole detector mass spectrometry (UPLC-QDa) method for the simultaneous quantification of tazarotene and tazarotenic acid, its active metabolite, in porcine skin. Method development involved a design-of-experiments approach for chromatographic optimization of gradient steepness, organic solvent volume, column temperature, capillary voltage, flow rate, and cone voltage. Central composite orthogonal design was used to optimize peak area, peak width, retention time, and resolution.

View Article and Find Full Text PDF

As an innovative branch of electronics, intelligent electronic textiles (e-textiles) have broad prospects in applications such as e-skin, human-computer interaction, and smart homes. However, it is still a challenge to distinguish multiple stimuli in the same e-textile. Herein, we propose a dual-parameter smart e-textile that can detect human pulse and body temperature in real time, with high performance and no signal interference.

View Article and Find Full Text PDF

An automated micro-tweezers system with a flexible workspace would benefit the intelligent sorting of live cells. Such micro-tweezers could employ a forced vortex strong enough to capture a single cell. Furthermore, addressable control of the position to the vortex would constitute a robotic system.

View Article and Find Full Text PDF

Dynamic pathophysiological features of early primary blast lung injury: a novel functional incapacity pig model.

Eur J Trauma Emerg Surg

January 2025

Department of Military Traffic Injury Prevention and Control, Daping Hospital, Army Medical University, Chongqing, 400042, China.

Introduction: While there is evidence supporting the use of ultrasound for real-time monitoring of primary blast lung injury (PBLI), uncertainties remain regarding the timely detection of early PBLI and the limited data correlating it with commonly used clinical parameters. Our objective is to develop a functional incapacity model for PBLI that better addresses practical needs and to verify the early diagnostic effectiveness of lung ultrasound in identifying PBLI.

Methods: We selected six healthy male pigs to develop an animal model using a bio-shock tube (BST-I).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!