Objective: Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples.
Methods: A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset.
Results: Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62 mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36).
Conclusion: The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/HJH.0000000000000778 | DOI Listing |
Sci Rep
January 2025
Praxis Dr.Carmine, Etzelstrasse 21, Pfaeffikon SZ, 8808, Switzerland.
Spot-urinary biomarkers are crucial in medical, epidemiological, and environmental studies, but their variability due to hydration levels requires precise dilution adjustments. Traditional methods, like conventional creatinine correction (CCRC), are limited in compensating for variations in urine concentration, causing substantial inconsistencies, particularly at the extremes of the diuresis spectrum. While restricting the creatinine (CRN) range to 0.
View Article and Find Full Text PDFNano Lett
January 2025
Science for Life Laboratory, Department of Women's and Children's Health, Karolinska Institutet, Tomtebodavägen 23, 17165 Solna, Sweden.
Single particle profiling (SPP) is a unique methodology to study nanoscale bioparticles such as liposomes, lipid nanoparticles, extracellular vesicles, and lipoproteins in a single particle and high throughput manner. The initial version requires the single photon counting modules for data acquisition, which limits its adoptability. Here, we present imaging-based SPP (iSPP) that can be performed by imaging a spot over time in the common imaging mode with confocal detectors.
View Article and Find Full Text PDFNiger Med J
January 2025
Department of Haematology and Blood Transfusion, Rivers State University Teaching Hospital & Faculty of Basic Clinical Sciences, Rivers State University, Nigeria.
Background: Microalbuminuria, an early indicator of kidney damage in Sickle Cell Disease (SCD) patients, is linked to a heightened risk of chronic kidney disease (CKD) in adulthood. This study investigates the determinants of microalbuminuria in paediatric SCD patients in South-South Nigeria.
Methodology: This cross-sectional study was conducted over six months at the Rivers State University Teaching Hospital, Nigeria, involving 60 children with [HbSS genotype, SCD] in a steady state.
Void spot assay (VSA) noninvasively evaluates urination. VSA is often not performed in rats due to difficulty analyzing larger papers compared with mouse. This study optimizes VSA for rats by comparing post-assay visualization techniques: bright field light (BF), ultraviolet light (UV), and ninhydrin spray (N).
View Article and Find Full Text PDFJ Trace Elem Med Biol
January 2025
Reproduction, Mother and Child Health Unit, Research Center of the CHU de Québec, Université Laval, Québec City, Québec, Canada; Department of Obstetrics, Gynecology and Reproduction, CHU de Québec-Université Laval, Québec City, Québec, Canada. Electronic address:
Background: Adequate maternal iodine intake is important for fetal brain development. Based on iodine intakes of non-pregnant females of reproductive age from the Canadian Health Measures Survey (2016 -2017) it can be extrapolated that most pregnant females in Canada will not meet iodine requirements without supplementation.
Objectives: To assess iodine intakes of 500 pregnant, nulliparous females from Québec, Canada and report on use of multivitamin/mineral (MVM) supplements and coverage of iodized salt.