Background: Large ventral hernia repair represents a major reconstructive surgical challenge, especially under contaminated conditions. Synthetic mesh is usually avoided in these circumstances because of fear of mesh infection, although evidence is outdated and does not regard new materials and techniques. The authors evaluated the safety of synthetic mesh in large contaminated ventral hernia repair.

Methods: All large ventral hernias repaired with the components separation technique and polypropylene mesh were included in analysis. Primary outcomes were wound and medical complications, with a focus on surgical-site infection and mesh removal. For risk analysis, patients were stratified by surgical wound class, Ventral Hernia Working Group grade, and modified Ventral Hernia Working Group grade.

Results: One hundred thirty-seven patients were included, with a mean age of 58.6 years, mean body mass index of 26.6 cm2, and mean defect size of 235.6 cm2. Surgical-site infection and total wound complication rates were 16.1 and 48.9 percent, respectively. The surgical wound class distribution of surgical-site infections was as follows: clean, five of 56 (9.1 percent); clean-contaminated, five of 34 (14.7 percent); contaminated, three of 19 (15.8 percent); and dirty/infected, nine of 28 (32.1 percent). Seven meshes (5.1 percent) needed removal, two after clean repairs, three after clean-contaminated repairs, and two after dirty/infected repairs. Surgical wound class (OR, 1.77; 95 percent CI, 1.20 to 2.61) and Ventral Hernia Working Group grade (OR, 2.31; 95 percent CI, 1.24 to 4.28) were predictors of surgical-site infection.

Conclusion: Rate of surgical-site infection after large contaminated ventral hernia repair with synthetic mesh is considerable but with a low mesh removal rate.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PRS.0000000000001793DOI Listing

Publication Analysis

Top Keywords

ventral hernia
28
synthetic mesh
16
large contaminated
12
contaminated ventral
12
hernia repair
12
surgical-site infection
12
surgical wound
12
wound class
12
hernia working
12
working group
12

Similar Publications

Introduction: Repair of midsize (4-6 cm) ventral hernias is challenging given lack of guidelines. Within this context, we sought to characterize surgical approach among patients undergoing repair of midsize ventral hernias within the only population-level, clinically-nuanced hernia registry in the US.

Methods: Retrospective cohort study of patients undergoing ventral hernia repair in the Michigan Surgical Quality Collaborative Core Optimization Hernia Registry (MSQC-COHR).

View Article and Find Full Text PDF

Self-gripping versus polypropylene mesh for incisional hernia repair in a rat model.

Surg Endosc

January 2025

Department of Hernia and Abdominal Wall Surgery, The First Affiliated Hospital of Zhengzhou University, No.1 Jianshe Road, Zhengzhou, 450052, Henan, China.

Background: Self-gripping mesh, made of monofilament polypropylene and covered by a layer of polylactic acid micro-hooks, is applied in ventral hernia repair, whereas cytological change and collagen expression around the mesh are rarely reported. The objective of this research was to compare inflammatory response and collagen proliferation between self-gripping and polypropylene mesh in rat model of incisional hernia.

Methods: Forty-five rats were randomly divided into unrepaired (UR) group, polypropylene (PP) mesh group, and self-gripping (SG) mesh group and euthanized at 1, 2 and 4 weeks postoperatively.

View Article and Find Full Text PDF

Introduction: The classic open ventral hernia repair provides excellent results in recurrences. However, wound complications are the Achilles heel for a good overall clinical outcome. Laparoscopic surgery is in general associated with less pain, better esthetic results, faster recovery, and lower incidence of wound complications.

View Article and Find Full Text PDF

A nulliparous woman in her 40s is referred to gynaecological oncology secondary to umbilical pain and bleeding with menses. Examination revealed a blood-filled cystic mass within an umbilical hernia consistent with umbilical endometrioma. The patient exhausted medical management options, then pursued surgical management via umbilectomy, excision of umbilical endometriosis, lysis of adhesions and umbilical hernia repair.

View Article and Find Full Text PDF

Placental Membrane Transplantation: Can It Be A Solution For Tissue Defect Repair In Giant Omphaloceles.

Transplant Proc

January 2025

Department of Perinatology, Istanbul Zeynep Kamil Maternity and Children's Diseases Health Training and Research Center, University of Health Sciences, Istanbul, Turkey. Electronic address:

Objectives: This study aimed to evaluate the effect of placental membrane covering of the omphalocele sac on the healing of giant omphaloceles requiring silo repair that could not be treated primarily.

Methods: This prospective study was performed between October 2021 and October 2023 with the approval of our hospital's ethics committee. All pregnant women diagnosed with prenatal giant omphalocele were informed that their own placenta could be used for omphalocele repair if necessary, and their consent was obtained.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!