Stent misplacement during endovascular treatment of middle cerebral artery (MCA) aneurysms can cause challenges and be problematic, if clipping becomes necessary. This article reports on a 56-year-old woman with an unruptured, multi-lobulated MCA aneurysm, whom primarily refused surgery; therefore, she was scheduled for stent-assisted coiling. After successful deployment of the stent, it unfortunately then became snagged by the microcatheter and was pulled backwards. The subsequent surgical procedure (i.e. clipping of the MCA aneurysm) was challenging, due to the position of the dislodged stent. Such as misplacement of the stent is rarely documented: It resulted in the difficult handling of a MCA aneurysm. Aneurysms of the MCA should primarily be considered for surgical clipping. In conclusion, an increased risk for eventual surgery should be considered, in cases where endovascular treatments with stents are performed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4757380 | PMC |
http://dx.doi.org/10.1177/1591019915617313 | DOI Listing |
Phys Med Biol
December 2024
Centre Hospitalier Universitaire (CHU) de Québec - Université Laval 2705, 2705, boul. Laurier (T1-61a) - CR-CHU-CHUL, Québec (Québec), Canada,, Québec, Québec, Quebec, G1V 4G2, CANADA.
Objective: Biodegradable cardiovascular stents made of thin, low atomic number metals (e.g. Zn, Mg, Fe) are now approved for clinical use.
View Article and Find Full Text PDFJ Invasive Cardiol
December 2024
Department of Radiology, Wuhan Asia Heart Hospital Affiliated to Wuhan University of Science and Technology, Wuhan, China. Email:
J Vasc Surg
January 2025
Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. Electronic address:
Objective: To report technical success and evaluate clinical outcomes of fenestrated and branched endovascular aortic repair (F/B-EVAR) incorporating a contralateral inverted limb.
Methods: Patients who underwent F/B-EVAR with a custom-made bifurcated device containing an inverted limb between January 2010 and September 2023 were retrospectively analyzed. Time-to-event data were analyzed using the Kaplan-Meier method.
Radiol Case Rep
November 2024
Department of radiology, section of interventional radiology, Baylor college of Medicine, Houston, TX, USA.
Endovascular stenting of the pulmonary artery treats arterial stenosis from pulmonary hypertension, congenital heart defects, or post-transplant stricture. Patients with malignant extrinsic pulmonary arterial compression, secondary to large mediastinal or pulmonary masses, often present with dyspnea, hypoxemia, and right ventricular failure. Conventional therapies like surgery, chemotherapy, and radiation are often slow and fail to promptly resolve acute symptoms.
View Article and Find Full Text PDFEndoscopy
December 2024
Department of Gastroenterology and Hepatology, CHU UCL Namur, Université catholique de Louvain, Yvoir, Belgium.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!