Objective: The purpose of this study was to compare a cerebral CT venography (CTV) technique performed on a 320-MDCT scanner with the use of a time-density curve (TDC) and a small volume of IV contrast medium (35 mL, with 15 mL used for the test bolus) with CTV performed using an established reference technique in which scanning is performed at a fixed time delay of 30 seconds with the use of a larger volume of contrast medium (100 mL).

Materials And Methods: The time of peak enhancement was determined from the TDC generated from a scan in which a test bolus dose was used. CTV was performed at the time of peak enhancement. The diagnostic quality of 31 CTV venograms acquired using this technique was compared retrospectively with the diagnostic quality of 29 CTV venograms obtained at a fixed time delay of 30 seconds. The densities in the major venous sinuses and the degree of arterial contamination on the scans acquired using the two techniques were compared using objective and semiobjective methods. The semiobjective assessments were made independently by two neuroradiologists.

Results: Attenuation was higher in the venous structures seen on CTV images acquired using the TDC technique. Of the scans obtained using the TDC technique, the proportion deemed to be of good quality, on the basis of a grading scale, was statistically significantly higher (p < 0.05). Also, the degree of arterial contamination was statistically significantly lower (p < 0.05). The interrater agreement for semiobjective assessments ranged from good to very good.

Conclusion: We describe a CTV technique performed using a low volume of IV contrast medium and a TDC on a 320-MDCT scanner. This technique provides better venous opacification and lower arterial contamination compared with use of the fixed time-delay technique.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.14.14200DOI Listing

Publication Analysis

Top Keywords

volume contrast
16
320-mdct scanner
12
contrast medium
12
arterial contamination
12
technique
10
cerebral venography
8
scanner time-density
8
time-density curve
8
low volume
8
fixed time-delay
8

Similar Publications

Event cameras only report changes in brightness when thresholds in individual pixels relative to previous levels are crossed. They output sparse streams of events that quantify these changes spatially and temporally. We have developed a measurement system using two event cameras in a stereo configuration with a specialized projector for 3D measurements of static objects.

View Article and Find Full Text PDF

Quantitative phase imaging (QPI) has become a valuable tool in the field of biomedical research due to its ability to quantify refractive index variations of live cells and tissues. For example, three-dimensional differential phase contrast (3D DPC) imaging uses through-focus images captured under different illumination patterns deconvoluted with a computed 3D phase transfer function (PTF) to reconstruct the 3D refractive index. In conventional 3D DPC with semi-circular illumination, partially spatially coherent illumination often diminishes phase contrast, exacerbating inherent noise, and can lead to a large number of zero values in the 3D PTF, resulting in strong low-frequency artifacts and deteriorating imaging resolution.

View Article and Find Full Text PDF

Background: Early and continuous exposure to painful stimuli in premature infants leads to short-and long-term complications. Listening to white noise is an accessible and inexpensive non-invasive method that can be used as a safe nursing intervention in hospitals. This study aimed to assess white noise's effect on premature Infants' physiological parameters during peripheral intravenous catheter insertion.

View Article and Find Full Text PDF

The motor symptoms of Parkinson's Disease are attributed to the degeneration of dopamine neurons in the substantia nigra pars compacta (SNc). Previous work in the MCI-Park mouse model has suggested that the loss of somatodendritic dopamine transmission predicts the development of motor deficits. In the current study, brain slices from MCI-Park mice were used to investigate dopamine signaling in the SNc prior to and through the onset of movement deficits.

View Article and Find Full Text PDF

Towards contrast-agnostic soft segmentation of the spinal cord.

Med Image Anal

January 2025

NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montréal, Montréal, Québec, Canada; Mila - Québec Artificial Intelligence Institute, Montréal, Québec, Canada; Functional Neuroimaging Unit, CRIUGM, University of Montreal, Montreal, Québec, Canada; Centre de recherche du CHU Sainte-Justine, Université de Montréal, Montréal, Québec, Canada. Electronic address:

Spinal cord segmentation is clinically relevant and is notably used to compute spinal cord cross-sectional area (CSA) for the diagnosis and monitoring of cord compression or neurodegenerative diseases such as multiple sclerosis. While several semi and automatic methods exist, one key limitation remains: the segmentation depends on the MRI contrast, resulting in different CSA across contrasts. This is partly due to the varying appearance of the boundary between the spinal cord and the cerebrospinal fluid that depends on the sequence and acquisition parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!