Engineering and characterization of simplified vaginal and seminal fluid simulants.

Contraception

Department of Bioengineering, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA; Department of Obstetrics and Gynecology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA. Electronic address:

Published: April 2016

Background: Reported vaginal and seminal fluid simulants have complex compositions with multiple preparatory steps that contribute to physical instability. We report the design and characterization of stable and simplified buffers that mimic the salient physical/chemical properties of the physiological fluids.

Study Design/methods: Human cervicovaginal and seminal fluid samples were collected and buffering capacity was determined. The major buffering species were identified from published compositions of reproductive tract fluids. These values were used to compute the composition of vaginal and seminal fluid simulants. Ionic strength, buffering capacities, pH and osmolalities were then calculated or experimentally determined. Finally, cytotoxicity was evaluated in HEC-1-A cells and 3D reconstructed EpiVaginal™ tissue (VEC-100-FT) using naïve cells/tissue and nonoxynol-9 as controls.

Results: The use of calculated amounts of conjugate acid and base for buffer development resulted in compositions that did not require endpoint pH adjustment and could be formulated as stable 10× concentrates. Furthermore, due to the absence of complex divalent salts, all our proposed simulants were stable at 4 °C for 1 month whereas precipitation and pH and osmolality changes were noted in reported buffers. Experimental determination of buffering capacities yielded similar values for undiluted cervicovaginal fluid (β4.2-5.2=35.6 ± 12.3 mM, N=7) and human seminal fluid (β7-6=37.5 ± 5 mM, N=3). All neat simulants showed significant cytotoxicity in HEC-1-A cells but were well tolerated by organotypic vaginal tissue.

Conclusions: We report revised and improved compositions of buffers mimicking salient properties of vaginal and seminal fluid necessary for in vitro product evaluation.

Implications: To support research in reproductive health and in particular drug delivery, we have designed and characterized stable new media to mimic these important fluids that can be used in a variety of in vitro studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4863460PMC
http://dx.doi.org/10.1016/j.contraception.2015.11.008DOI Listing

Publication Analysis

Top Keywords

seminal fluid
24
vaginal seminal
16
fluid simulants
12
buffering capacities
8
hec-1-a cells
8
fluid
7
seminal
6
vaginal
5
simulants
5
engineering characterization
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!