Introduction: Ultrasound-assisted external fixation of long bones has the potential to enhance extremity damage control surgery in locations without fluoroscopy, such as forward surgical elements, the intensive care unit, and spacecraft. This pre-clinical study specifically sought to evaluate orthopaedic surgeons' ability to sonographically define fracture patterns and the associated zone of injury in order to improve surgical decision-making and safely insert Schanz pin percutaneously.

Methods: We encased small composite femurs in a cylindrical echogenic gelatin matrix to simulate a human thigh. Three orthopaedic trauma surgeons with no prior ultrasound experience were taught to use sonography to diagnose fractures and assist external fixation. The surgeons were then presented with five specimens in a randomized sequence: three diaphyseal fractures (32-A2, 32-C2 and 32-C3); a distal femur fracture (33-A1.2); and an intact femur, all encased in an opaque black gelatin matrix to blind the participants to the underlying pathology. If they diagnosed a diaphyseal fracture, the surgeons were instructed to insert two Schanz pins proximal and two distal to the fracture, no closer than 40 mm from the fracture edges.

Results: Fracture diagnosis and surgical decision-making were correct in all cases. All intact femurs were recognized as such. The need for a knee-spanning external fixator was recognized for all distal femur fractures. The three surgeons performed appropriate ultrasound-assisted pin placement in every case of diaphyseal fracture. The pins adjacent to the fracture site were on average 58 mm (SD ±11 mm) from the edge of the fracture. No pins were inserted in the fracture or in the knee joint.

Conclusions: The current study results suggest that with minimal training, orthopaedic surgeons can use portable ultrasound to diagnose femur fractures, decide the appropriate external fixator configuration, and safely insert Schanz pins outside the zone of injury.

Download full-text PDF

Source
http://dx.doi.org/10.1136/jramc-2015-000550DOI Listing

Publication Analysis

Top Keywords

external fixation
12
insert schanz
12
fracture
10
ultrasound-assisted external
8
zone injury
8
surgical decision-making
8
safely insert
8
gelatin matrix
8
distal femur
8
diaphyseal fracture
8

Similar Publications

Pelvic packing - status 2024.

Arch Orthop Trauma Surg

January 2025

Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.

Patients with unstable hemodynamics and unstable pelvic ring injuries are still demanding patients regarding initial treatment and survival. Several concepts were reported during the last 30 years. Mechanical stabilization of the pelvis together with hemorrhage control offer the best treatment option in these patients.

View Article and Find Full Text PDF

Ankle fractures are among the most common bone injuries, which are often accompanied by soft tissue injuries. Proper management of these fractures is crucial to promote healing and minimize complications. This study explores the effects of 2 treatment methods for ankle fractures: open reduction and internal fixation and manual reduction followed by plaster external fixation.

View Article and Find Full Text PDF

We present the case of a 64-year-old man who, during the implantation of an active-fixation leadless pacemaker (LP, Aveir VR, Abbott, USA), underwent several external defibrillation shocks up to 240 Joules, due to symptomatic sustained supraventricular tachycardia at 160 bpm. The shocks, delivered both before and after the screwing of the device in the low interventricular septum, did not cause any technical damage to the device, and no complications were observed. The device was then deployed successfully.

View Article and Find Full Text PDF

Subtrochanteric fractures in older patients are typically due to low-energy falls. The standard of care is intramedullary nailing. The Smith & Nephew Trigen Intertan (Memphis, TN, US) is an intramedullary nail with a novel design that incorporates two integrated compression screws.

View Article and Find Full Text PDF

Traumatic burst fractures of the atlas occur with axial loading of the cervical spine. Many of these injuries can be treated by nonsurgical management with external orthosis; however, cases with transverse ligament disruption or significant C1 lateral mass displacement require internal reduction and fixation. In patients with poor bone quality in the setting of osteoporosis or chronic illness, atlanto-axial fixation and reduction of the fracture can be a challenge, necessitating extension of fusion to the occiput, which significantly limits the range of motion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!