Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The goal of this study was to analyze how various incubation times affect the uptake of cholesterol on silicone hydrogel (SH) and conventional hydrogel (CH) daily disposable (DD) contact lens materials using an in vitro radiochemical detection method.
Methods: Three SH (somofilcon A, delefilcon A, and narafilcon A) and four CH (etafilcon A, nesofilcon A, ocufilcon A, and nelfilcon A) contact lenses were incubated in an artificial tear solution that contained major tear film components and a portion of radioactive C-cholesterol. Lenses (N = 4) were incubated for four incubation times (2, 6, 12, or 16 h) to assess the effects on cholesterol deposition. Subsequent to the incubation, the lenses were extracted using 2:1 chloroform:methanol, and the extracts were analyzed in a beta counter and (in nanograms per lens) extrapolated from standard curves.
Results: In general, cholesterol deposited statistically significantly more on SH lenses than CHs (p ≤ 0.033), with the exception of somofilcon A and nesolfilcon A materials (p = 0.067). Within the SH materials, narafilcon A accumulated the largest quantity of cholesterol (p < 0.05) and somofilcon A the lowest (p < 0.05). The uptake of cholesterol ranged from 22.63 ± 2.98 ng/lens to 97.94 ± 4.18 ng/lens for all lens materials. The accumulation of cholesterol was shown to be continuous throughout the 16 h of incubation, without reaching a plateau (p < 0.001).
Conclusions: For the periods that DD lens materials are worn, cholesterol deposits significantly more onto SH contact lenses than CHs. This could have implications for wearers who have higher levels of lipid in their tears that are fitted with SH DD materials.