Effects of Surface Modification and Bulk Geometry on the Biotribological Behavior of Cross-Linked Polyethylene: Wear Testing and Finite Element Analysis.

Biomed Res Int

Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan ; Orthopaedic Surgery, Sensory and Motor System Medicine, Surgical Sciences, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.

Published: August 2016

The wear and creep deformation resistances of polymeric orthopedic bearing materials are both important for extending their longevity. In this study, we evaluated the wear and creep deformation resistances, including backside damage, of different polyethylene (PE) materials, namely, conventional PE, cross-linked PE (CLPE), and poly(2-methacryloyloxyethyl phosphorylcholine)- (PMPC-) grafted CLPE, through wear tests and finite element analysis. The gravimetric and volumetric degrees of wear of disks (3 or 6 mm in thickness) of these materials against a cobalt-chromium-molybdenum alloy pin were examined using a multidirectional pin-on-disk tester. Cross-linking and PMPC grafting decreased the gravimetric wear of the PE disks significantly. The volumetric wear at the bearing surface and the volumetric penetration in the backside of the 3-mm thick PE disk were higher than those of the 6-mm thick PE disk, regardless of the bearing material. The geometrical changes induced in the PE disks consisted of creep, because the calculated internal von Mises stress at the bearing side of all disks and that at the backside of the 3-mm thick disks exceeded their actual yield strengths. A highly hydrated bearing surface layer, formed by PMPC grafting, and a cross-linking-strengthened substrate of adequate thickness are essential for increasing the wear and creep deformation resistances.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4637033PMC
http://dx.doi.org/10.1155/2015/435432DOI Listing

Publication Analysis

Top Keywords

wear creep
12
creep deformation
12
deformation resistances
12
wear
8
finite element
8
element analysis
8
wear disks
8
pmpc grafting
8
bearing surface
8
backside 3-mm
8

Similar Publications

Background: Experimental knee implant wear testing according to ISO 14243 is a standard procedure, but it inherently possesses limitations for preclinical evaluations due to extended testing periods and costly infrastructure. In an effort to overcome these limitations, we hereby develop and experimentally validate a finite-element (FE)-based algorithm, including a novel cross-shear and contact pressure dependent wear and creep model, and apply it towards understanding the sensitivity of wear outcomes to the applied boundary conditions.

Methods: Specifically, we investigated the application of in vivo data for level walking from the publicly available "Stan" data set, which contains single representative tibiofemoral loads and kinematics derived from in vivo measurements of six subjects, and compared wear outcomes against those obtained using the ISO standard boundary conditions.

View Article and Find Full Text PDF

Macroscale Superlubrication Achieved with Shear-Thinning Semisolid Lubricants.

Adv Mater

December 2024

State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, 730000, China.

Macrosuperlubric materials are pivotal for reducing friction and wear in engineering applications. However, current solid superlubricants require intricate fabrication and specific conditions (e.g.

View Article and Find Full Text PDF
Article Synopsis
  • TiAl alloys are lightweight and strong, making them suitable replacements for Ni-based superalloys in high-temperature situations.
  • Researchers created a new TiAl alloy (Ti4822) by adding niobium (Nb) and used laser metal deposition to examine how Nb affected the alloy's structure and properties.
  • The study found that increasing Nb promoted the desirable γ phase while reducing the β phase, leading to higher tensile strength, but also increased wear and friction rates due to specific wear mechanisms.
View Article and Find Full Text PDF

High performances of cellulose nanocrystal based bicomponent supramolecular hydrogel lubricant.

Carbohydr Polym

November 2024

School of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha 410000, China; Hunan Province Key Laboratory of Materials Surface, Interface Science and Technology, Changsha 410000, China.

Article Synopsis
  • A novel hydrogel made from cellulose nanocrystal (CNC) and diglycerol (DG) was developed to address the drawbacks of water-based lubricants.
  • The gel's formation relies on a network of hydrogen bonds that helps hold water, and it has been shown to have excellent viscoelasticity, thermal stability, and anti-rust properties.
  • Testing on a specific hydrogel composition (CNC/2.4-DG/0.1) revealed it outperformed traditional lubricants in friction and wear, thanks to the combined effects of CNC and DG.
View Article and Find Full Text PDF

Natural cartilage exhibits superior lubricity as well as an ultra-long service lifetime, which is related to its surface hydration, load-bearing, and deformation recovery feature. Until now, it is of great challenge to develop reliable cartilage lubricating materials or coatings with persistent robustness. Inspired by the unique biochemical structure and mechanics of natural cartilage, the study reports a novel cartilage-hydrogel composed of top composite lubrication layer and bottom mechanical load-bearing layer, by covalently manufacturing thick polyelectrolyte brush phase through sub-surface of tough hydrogel matrix with multi-level crystallization phase.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?