Background: Robot-assisted radical prostatectomy (RARP) is a widespread option for the treatment of patients with clinically localised prostate cancer. Modifications in the surgical technique may help to further improve functional outcomes.
Objective: To assess the outcome of early catheter removal 48h after surgery, as opposed to standard catheter removal 6 d after surgery following RARP, using a newly developed surgical technique for posterior reconstruction and anastomosis (Aalst technique).
Design, Setting, And Participants: Patients scheduled for RARP were prospectively scheduled for early catheter removal at postoperative d 2 (group A, n=37) and standard catheter removal at postoperative d 6 (group B, n=37).
Surgical Procedure: RARP was performed using the Da Vinci Si system. The Aalst technique for the urethro-vesical anastomosis including posterior reconstruction was used as previously described.
Outcome Measurements And Statistical Analysis: The primary endpoint was spontaneous voiding after catheter removal. Secondary endpoints were rate of anastomotic urinary leakage after catheter removal, presence and severity of urethral, perineal, and abdominal pain, as well as patient's bother after catheter removal using visual analogue scale (VAS) scores. Rate and severity of urinary incontinence after catheter removal were assessed using the International Consultation on Incontinence Questionnaire-Male Lower Urinary Tract Symptoms Module (ICIQ-MLUTS) questionnaire.
Results And Limitations: There was no significant difference between the groups with regard to baseline and perioperative parameters, as well as pathological features; however, significantly more patients underwent bilateral nerve-sparing procedures in group A (34 vs 23, p=0.008). After catheter removal, patients in both groups showed spontaneous voiding, whereas only 11% and 8% of the patients in group A and group B experienced urinary retention after catheter removal (p=0.7). Patients in group B had significantly higher maximum flow rates, but lower voided volumes after catheter removal in comparison with patients in group A (21ml/s vs 10ml/s, p≤0.001 and 170ml vs 200ml, p≤0.001, respectively). ICIQ-MLUTS questionnaire and VAS scores showed no significant differences between the groups at any time point.
Conclusions: The Aalst technique allows the removal of catheters 2 d after RARP and results in spontaneous voiding. Early removal showed no increased rate of urinary leakage, no negative impact on short-term continence and on perineal, urethral or penile pain, and no increase in urinary retention rates. Future studies have to confirm these results with longer follow-up including detailed parameters on return to daily activity.
Patient Summary: We provide evidence that it is possible to remove the bladder catheter as early as 2 d after robot-assisted radical prostatectomy without any negative effects on voiding and pain parameters. Thus, leaving the hospital early without a catheter in place could represent a significant and relevant benefit for the patient.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.eururo.2015.09.052 | DOI Listing |
Int J Surg Case Rep
January 2025
Department of Surgery, College of Medicine and Health Sciences, Comprehensive Specialized Hospital, University of Gondar, Gondar, Ethiopia.
Introduction And Importance: Myiasis is an overlooked public health issue, with urogenital myiasis (UGM) being particularly rare, as evidenced by only 59 reported cases worldwide from 1975 to 2017. There is a notable scarcity of cases involving patients with prolonged catheter use related to SCI. The interaction of SCI with the complications associated with indwelling urinary devices is less frequently discussed in prior literature.
View Article and Find Full Text PDFPathogens
December 2024
Intensive Care Unit, Department of Anesthesiology and Critical Care, AHEPA University Hospital, Aristotle University of Thessaloniki, 54636 Thessaloniki, Greece.
Ventriculo-meningitis or nosocomial meningitis/ventriculitis is a severe nosocomial infection that is associated with devastating neurological sequelae. The cerebrospinal fluid isolates associated with the infection can be Gram-positive or -negative, while the spp. is rarely identified.
View Article and Find Full Text PDFAntibiotics (Basel)
January 2025
Unit II, Department of Infectious Diseases, Luigi Sacco Hospital, ASST Fatebenefratelli Sacco, 20157 Milan, Italy.
: Vascular access device (VAD)-associated infections, including catheter-related (CRBSI) and catheter-associated bloodstream infections (CABSI), present significant challenges in patient care. While multidisciplinary VAD teams (VATs) are equipped with protocols for managing these infections, adherence to these guidelines in real-life practice is inconsistent. This study aims to evaluate the alignment between actual VAD infection management practices and VAT-recommended protocols.
View Article and Find Full Text PDFBeijing Da Xue Xue Bao Yi Xue Ban
February 2025
Department of Nephrology, Peking University People's Hospital, Beijing 100044, China.
Objective: Peritoneal dialysis(PD)-associated peritonitis is a common and major complication of PD and the most common cause of technical failure of PD. The presence of bacterial biofilm may be an important factor leading to refractory or recurrence of peritonitis. To investigate the formation and characteristics of bacterial biofilms on PD catheters after peritonitis-associated catheter removal.
View Article and Find Full Text PDFBMJ Open
January 2025
School of Nursing & Midwifery, University of Galway, Galway, Ireland.
Introduction: The peripheral vascular catheter (PVC) is the most common intravenous medical device used in hospitals, given it is crucial for the delivery of intravenous therapies. Despite its widespread use, PVC complications such as occlusion, infiltration, extravasation, phlebitis, thrombophlebitis, catheter-related thrombosis and catheter-related bloodstream infection significantly affect patient safety, leading to increased morbidity and healthcare costs. One approach to maintain PVC patency and therefore device longevity is to flush the PVC.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!