Reliability of eccentric position of the pedicle instead of central position in a thoracodorsal artery perforator flap.

Microsurgery

Department of Plastic and Reconstructive Surgery, College of Medicine, Seoul National University, Seoul National University Hospital, Seoul, Korea.

Published: January 2017

Introduction: To obtain longer vascular pedicle in perforator flaps, surgeons often use eccentrically rather than centrally located perforators. The aim of this study was to compare the safety and reliability of thoracodorsal artery perforator (TDAP) flaps harvested with centrally or eccentrically located perforators.

Methods: Between January 2008 and March 2012, 100 TDAP flaps were used to reconstruct the lower extremity defects. Flaps longer than 10 cm, with a single musculocutaneous perforator, and one artery-one vein anastomoses were included. The cases were divided into two groups according to perforator location; Central perforators in 60 cases (group 1), and peripheral perforators in 40 cases (group 2). Total pedicle length was between the points where the perforator enters the flap to the end of the pedicle. Real pedicle length was from flap margin to the end of the pedicle. The flap dimension, total pedicle length, real pedicle length, and flap related complications were measured.

Results: The flaps were smaller in group 1 than in group 2 (159.6 ± 94.08 vs.189.95 ± 134.30 cm , P = 0.455). Total pedicle length was almost the same (12.12 ± 1.57 vs.12.88 ± 2.10 cm, P = 0.420), but the mean real pedicle length was longer in group 2 (6.13 ± 1.33 vs.11.65 ± 2.08 cm, P < 0.05). There were 4 cases of partial loss of flap in group 1 and 3 partial loss and one total flap loss in group 2 without significant difference (P = 0.547).

Conclusions: Using eccentrically located perforators is simple method of extending real pedicle length, but there have been concerns regarding flap perfusion and distal vascularity. Our findings suggest that, in TDAP flaps, both eccentric and central perforator are safe options. © 2014 Wiley Periodicals, Inc. Microsurgery 37:44-48, 2017.

Download full-text PDF

Source
http://dx.doi.org/10.1002/micr.30004DOI Listing

Publication Analysis

Top Keywords

pedicle length
24
total pedicle
12
real pedicle
12
pedicle
10
thoracodorsal artery
8
artery perforator
8
tdap flaps
8
perforators cases
8
cases group
8
length flap
8

Similar Publications

Objective: To investigate the predictive ability of the MRI-based vertebral bone quality (VBQ) score for pedicle screw loosening following instrumented transforaminal lumbar interbody fusion (TLIF).

Methods: Data from patients who have received one or two-level instrumented TLIF from February 2014 to March 2015 were retrospectively collected. Pedicle screw loosening was diagnosed when the radiolucent zone around the screw exceeded 1 mm in plain radiographs.

View Article and Find Full Text PDF

Study Design: Retrospective Cohort Study.

Objectives: Flexibility radiographs such as traction or bending radiographs are essential in preoperative imaging to assess for curve flexibility and to estimate the amount of operative correction in order to determine the type and length of instrumentation in growth-accompanying scoliosis treatment. Both traction and bending radiographs are controversially discussed in the literature.

View Article and Find Full Text PDF

Injuries involving the Atlas (C1) and Axis (C2) vertebrae of the cervical spine present significant clinical challenges due to their complex anatomy and potential for severe neurological impairment. Traditional imaging methods often lack the detailed visualization required for precise surgical planning. This study aimed to develop high-resolution 3D models of the C1 and C2 vertebrae to perform a comprehensive morphometric analysis, identify gender differences, and assess bilateral symmetry to enhance surgical accuracy.

View Article and Find Full Text PDF

Objective: Awake, endoscopic spinal fusion has been utilized as an ultra-minimally invasive surgery technique to accomplish the goals of spinal fixation, fusion, and disc height restoration. While many techniques exist for this approach, this series represents a single institution's experience with a large cohort and the evolution of this method.

Methods: The medical records of a consecutive series of 400 patients treated over a 10-year period were retrospectively reviewed.

View Article and Find Full Text PDF

Spine surgery has undergone significant advancements, particularly with regard to robotic systems that enhance surgical techniques and improve patient outcomes. As these technologies become increasingly integrated into surgical practice, it is essential to evaluate their added value and cost savings. Hence, this study compared robot-assisted and navigation-based spine surgery, focusing on surgical efficiency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!