Objectives: The aim of this study was to obtain quantitative data related to the activity of each head of the pronator quadratus based on dynamic sonographic parameters during gripping effort and to assess their relationships with grip and pronation strengths.
Methods: The forearms of 33 healthy volunteers were evaluated at 5 positions of axial rotation (full supination, 45° supination, neutral, 45° pronation, and full pronation). Echogenic intensity ratios and muscle thicknesses of each head of the pronator quadratus were measured from transverse cross-sectional sonograms obtained during maximal grip and release. Grip strengths and maximal isokinetic pronation torques at 90°/s and 360°/s were evaluated as strength parameters and correlated with sonographic measures.
Results: Echogenic intensity ratios of both heads significantly decreased during power grip (P ≤ .002). Changes in echogenic intensity ratios of the superficial head were greater when the forearm was pronated compared to supination (P < .001), whereas changes in echogenic intensity ratios of the deep head were constant at all forearm positions. Muscle thicknesses of the superficial head maximally increased at the neutral position during power grip (P < .001), whereas muscle thicknesses of the deep head did not change. There were significant negative correlations between grip strength and echogenic intensity ratios of both heads at all respective forearm positions (P ≤ .048). Pronation torque was significantly correlated with echogenic intensity ratios of the superficial head at all forearm positions and the deep head at 45° and full pronation positions (P ≤ .034).
Conclusions: The data revealed that the superficial head of the pronator quadratus more actively contracts when the forearm is in pronation, whereas the deep head constantly contracts at all positions. This study suggests that both heads of the pronator quadratus also play a role in grip strength, but the superficial head contributes more to pronation strength.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.7863/ultra.15.02038 | DOI Listing |
Colloids Surf B Biointerfaces
January 2025
Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu 42988, Republic of Korea. Electronic address:
In recent years, the design of various ultrasound responsive echogenic nanomaterials offers many advantages such as deep tissue penetration, high signal intensity, colloidal stability, biocompatibility and less expensive for ultrasound-based cancer cell imaging while providing the option to monitor the progress of tumor volume during the treatment. Further, the ability of nanomaterials to combine photo-thermal therapy (PTT) and chemotherapy has opened a new avenue in the development of cancer theranostics for synergistic cancer therapy. Herein, we report MoS nanoflowers (NFs) surface decorated with CuS nanorods (NRs) and folic acid-derived carbon dots (FACDs) using cystine-polyethyleneimine (PEI) linker for PTT-chemotherapy.
View Article and Find Full Text PDFBioengineering (Basel)
December 2024
Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.
J Ultrasound Med
December 2024
Department of Ultrasound, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
Objectives: Current literature on imaging characteristics of hepatic inflammatory pseudotumor (HIPT) is limited. This study aimed to analyze the contrast-enhanced ultrasound (CEUS) features in HIPT and compare them with contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CEMRI).
Methods: A total of 83 patients with histologically proven HIPT from two medical institutions were included in this study.
Cancers (Basel)
November 2024
Department of Dermatology, Poznan University of Medical Sciences, 61-701 Poznań, Poland.
Objectives: Actinic keratoses (AKs) are one of the most common reasons for consultation in the elderly population. This study aimed to assess the efficacy of 5-ALA PDT in AK treatment using high-frequency ultrasonography (HFUS) to evaluate skin layer changes during therapy.
Methods: In our study, we included 44 AK patients aged 53 to 89 years.
Clin Endocrinol (Oxf)
February 2025
Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China.
Background: A small number of thyroid nodules cannot be clearly diagnosed using ultrasound-guided fine needle aspiration biopsy. Contrast-enhanced ultrasound (CEUS) has high diagnostic performance for thyroid nodules. We explored the value of CEUS for diagnosing thyroid nodules with indeterminate cytology.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!