Study Design: Antimicrobial effect of a novel silver-impregnated pedicle screw in rabbits.
Objective: A novel spine implant model was designed to study the antimicrobial effect of a modified Titanium (Ti) pedicle screws with methicillin-resistant Staphylococcus aureus (MRSA) in multiple surgical sites in the lumbar spine of a rabbit.
Summary Of Background Data: Infection in spinal implant is of great concern. Anti-infection strategies must be tested in relevant animal models that will lead to appropriate clinical studies.
Methods: Fourteen New Zealand white rabbits were divided into 2 groups: group 1: infected unmodified Ti screw group (n = 6), and group 2: infected polyethylene glycol grafted, polypropylene-based silver nanoparticle (PP-g-PEG-Ag) covered Ti screw group (n = 6), and 2 rabbits as sterile (sham-operated and control) group. In all groups, left L4-right L6 vertebra levels were exposed and screws were drilled to transverse processes after contamination of burr holes and surrounding tissue with 0.1 mL of 10 colony forming units (CFU) MRSA solutions in groups 1 and 2. After 21 days, samples were collected and infection was analyzed via light and scanning electron microscopy and culturing. Silver nanoparticles (Ag-NP) on the screws and tissues were assayed pre and postoperatively.
Results: The bacterial colony count for modified-Ti screw group was lower than for unmodified Ti screw (17.2 versus 200 x 10(3) CFU/mL, P = 0.029) with less biofilm formation. There was no difference in duration of surgery among groups and within the surgical sites. Ag-NPs were detected on the screw surface postoperatively.
Conclusion: This novel experimental design of implantation in rabbits is easy to apply and resembles human stabilization technique. Modified Ti screws were shown to have antimicrobial effect especially inhibiting the biofilm formation. This anchored Ag NPs that remained after 21st day of implantation shows that it is resistant to tapping forces of the screw.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BRS.0000000000001223 | DOI Listing |
Objectives: To report outcomes of femoral neck fractures (FNFs) treated with Femoral Neck System (FNS) and to compare the risks of later conversion to arthroplasty for FNS and fixation with cannulated screws (CNSs).
Design: A retrospective study.
Setting: A single-center study (Turku University Hospital, Finland).
Cureus
November 2024
Aerospace Engineering, Universiti Putra Malaysia, Kuala Lumpur, MYS.
Introduction Spinal fusion surgery with pedicle screws is commonly performed to stabilize the spine of osteoporotic patients. However, securing a strong screw fixation in osteoporotic bone presents significant challenges due to the reduced bone density. This study aimed to compare the biomechanical performance in an osteoporotic bone model of pedicle screws inserted using two different techniques, the Jamshidi needle technique and the pedicle probe technique, as well as the influence of tapping on both these techniques.
View Article and Find Full Text PDFCureus
November 2024
CISNE Spine Academy, Star Medica Hospital, Autonomous University of Chihuahua, Chihuahua, MEX.
Study Design: This is a cross-sectional survey.
Objectives: This study aimed to evaluate the availability and knowledge of navigation technologies for educational purposes and patient management in spine surgeons in Latin America.
Methods: A cross-sectional study was conducted among Latin American Spine Association members using a comprehensive 16-question survey to evaluate their knowledge and practices regarding navigation in spinal surgery.
Plast Aesthet Nurs (Phila)
December 2024
Sowmya Srinivas, BDS, MDS, PhD, is an Assistant Professor at the Department of Prosthodontics, JSS Dental College and Hospital, JSS Academy of Higher Education and Research, Mysore, Karnataka, India.
Placing an implant immediately into extraction sockets provides a distinct advantage over delayed placement, eliminating the need for a 4 to 6 months waiting period for bone formation. However, when patients present with hypothyroidism, the feasibility of immediate placement of dental implants becomes uncertain. This case involved a hypothyroid woman in her late 60s with loose lower anterior teeth.
View Article and Find Full Text PDFJ Neurosurg Spine
December 2024
1Department of Orthopaedic Surgery, The Och Spine Hospital/Columbia University Irving Medical Center, New York, New York.
Objective: The objective of this study was to compare a multiple pelvic screw fixation strategy (dual bilateral 4 pelvic screw fixation [4PvS]) with the use of single bilateral 2 pelvic screw fixation (2PvS), with the aim of addressing lumbosacral junction stability.
Methods: This analysis is a single-center, retrospective review of ASD patients treated between 2015 and 2021. All patients had a minimum 2-year follow-up and spinal fusion to the sacrum without sacroiliac fusion and met at least one radiographic and procedural criterion: pelvic incidence-lumbar lordosis ≥ 20°, T1 pelvic angle ≥ 20°, sagittal vertical axis ≥ 7.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!