Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: In post-dilution online hemodiafiltration (OL-HDF), the only recommendation concerning the dialysate, or dialysis fluid, refers to its purity. No study has yet determined whether using a high dialysate flow (Qd) is useful for increasing Kt or ultrafiltration-infusion volume.
Objective: Study the influence of Qd on Kt and on infusion volume in OL-HDF.
Material And Methods: This was a prospective crossover study. There were 37 patients to whom 6 sessions of OL-HDF were administered at 3 different Qds: 500, 600 and 700ml/min. A 5008(®) monitor was used for the dialysis in 21 patients, while an AK-200(®) was used in 17. The dialysers used were: 20 with FX 800(®) and 17 with Polyflux-210(®). The rest of the parameters were kept constant. Monitor data collected were effective blood flow, effective dialysis time, final Kt and infused volume.
Results: We found that using a Qd of 600 or 700ml/min increased Kt by 1.7% compared to using a Qd of 500ml/min. Differences in infusion volume were not significant. Increasing Qd from 500ml/min to 600 and 700ml/min increased dialysate consumption by 20% and 40%, respectively.
Conclusions: With the monitors and dialysers currently used in OL-HDF, a Qd higher than 500ml/min is unhelpful for increasing the efficacy of Kt or infusion volume. Consequently, using a high Qd wastes water, a truly important resource both from the ecological and economic points of view.