Objective: To investigate the placement of a long tube into the small intestine under fluoroscopic guidance and to evaluate its decompression effect on early postoperative small bowel obstruction (EPSBO).

Methods: Fifty-four patients with EPSBO requiring decompression between April 2010 and July 2014 were enrolled in the study. Insertion of a long tube was guided by fluoroscopy. We first used the guide wire to pass the pylorus and then used the 10 Fr feeding tube as an exchangeable tube to put the superstiff wire into the duodenum. Finally the long tube could be passed over the guide wire through the pylorus into the intestine. The total procedure time, the radiation exposure time, and the incidence of complications were evaluated.

Results: The long tubes passed into the jejunum on initial insertion for all patients, so the success rate of this technique was 100%. The long tube was inserted into ileum in 18 patients. The mean total procedure time was 34.4 ± 8.6 minutes, and the mean radiation exposure time 18.9 ± 6.8 minutes. A total of 47 patients (87%) experienced full recovery following long-tube decompression and without the need for surgical intervention.

Conclusions: Using the wire-exchange technique, it is easy to place a long tube into the small bowel under fluoroscopic guidance. This decompression method is safe and effective for management of EPSBO.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1001-9294(15)30040-7DOI Listing

Publication Analysis

Top Keywords

long tube
20
small bowel
12
fluoroscopic guidance
12
placement long
8
tube
8
early postoperative
8
postoperative small
8
bowel obstruction
8
tube small
8
guide wire
8

Similar Publications

Long segment ureteral reconstruction using the prepuce: A case report.

Urol Case Rep

January 2025

Department of Urology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430030, China.

Long segment ureteral reconstruction has always posed a challenge for surgeons. We report the case of a 49 years male patient with a right ureteral obstruction between the ileal orthotopic bladder and the ureter. The patient underwent a 12cm ureteral reconstruction with the prepuce.

View Article and Find Full Text PDF

Renal interstitial fibrosis (RIF) is a common pathway in chronic kidney disease (CKD) that ultimately leads to end-stage renal failure, worsening both glomerulosclerosis and interstitial fibrosis. Ten percent of the adult population in the world suffers from CKD, and as the ageing population continues to rise, it is increasingly regarded as a global threat-a silent epidemic. CKD has been discovered to be closely associated with both long noncoding RNAs (lncRNAs) and microRNAs (miRNAs), while the precise molecular processes behind this relationship are still unclear.

View Article and Find Full Text PDF

Charge detection mass spectrometry (CDMS) allows direct mass measurement of heterogeneous samples by simultaneously determining the charge state and the mass-to-charge ratio (/) of individual ions, unlike conventional MS methods that use large ensembles of ions. CDMS typically requires long acquisition times and the collection of thousands of spectra, each containing tens to hundreds of ions, to generate sufficient ion statistics, making it difficult to interface with the time scales of online separation techniques such as ion mobility. Here, we demonstrate the application of Fourier transform multiplexing and drift tube ion mobility joined with Orbitrap-based CDMS for the analysis of multimeric protein complexes.

View Article and Find Full Text PDF

For the purpose of assessing image quality and calculating patient X-ray dosage in radiology, computed tomography (CT), fluoroscopy, mammography, and other fields, it is necessary to have prior knowledge of the X-ray energy spectrum. The main components of an X-ray tube are an electron filament, also known as the cathode, and an anode, which is often made of tungsten or rubidium and angled at a certain angle. At the point where the electrons generated by the cathode and the anode make contact, a spectrum of X-rays with energies spanning from zero to the maximum energy value of the released electrons is created.

View Article and Find Full Text PDF

Objective: To gain insights into the experience, and impact, of using security staff to facilitate physical restraints for nasogastric tube feeding.

Design: A cross-sectional design using 39 individual interviews, three online focus groups and three written submissions involving young people with lived experience (PWLE), parents/carers, paediatric staff and security staff involved in nasogastric feeding under restraint in paediatric settings in England. Qualitative semistructured interviews were transcribed and thematically analysed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!