Background And Study Aims: Video capsule endoscopy (VCE) is invaluable in the diagnosis of small-bowel pathology. Capsule retention is a major concern in patients with Crohn's disease. The patency capsule was designed to evaluate small-bowel patency before VCE. However, the actual benefit of the patency capsule test in Crohn's disease remains unclear. The aim of this study was to evaluate the clinical impact of patency capsule use on the risk of video capsule retention in patients with established Crohn's disease.

Patients And Methods: This was a retrospective, multicenter study of patients with established Crohn's disease who underwent VCE for clinical need. The utilization strategy for the patency capsule was classified as selective (only in patients with obstructive symptoms, history of intestinal obstruction or surgery, or per treating physician's request) or nonselective (all patients with Crohn's disease). The main outcome was video capsule retention in the entire cohort and within each utilization strategy.

Results: A total of 406 patients who were referred for VCE were included in the study. VCE was performed in 132 /406 patients (32.5 %) without a prior patency capsule test. The patency capsule test was performed in 274 /406 patients (67.5 %) and was negative in 193 patients. Overall, VCE was performed in 343 patients and was retained in the small bowel in 8 (2.3 %). In this cohort, the risk of video capsule retention in the small bowel was 1.5 % without use of a prior patency capsule and 2.1 % after a negative patency test (P = 0.9). A total of 18 patients underwent VCE after a positive patency capsule test, with a retention rate of 11.1 % (P = 0.01). Patency capsule administration strategy (selective vs. nonselective) was not associated with the risk of video capsule retention.

Conclusions: Capsule retention is a rare event in patients with established Crohn's disease undergoing VCE. The risk of video capsule retention was not reduced by the nonselective use of the patency capsule. Furthermore, VCE after a positive patency capsule test in patients with Crohn's disease was associated with a high risk of video capsule retention.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0034-1393560DOI Listing

Publication Analysis

Top Keywords

patency capsule
48
crohn's disease
28
video capsule
28
capsule retention
28
capsule
20
capsule test
20
risk video
20
patients established
16
established crohn's
16
patency
14

Similar Publications

Patency Capsule and Cross-Sectional Imaging for Predicting Capsule Endoscopy Retention: A Systematic Review and Meta-Analysis.

Dig Dis Sci

January 2025

Department of Pediatrics, University of Ulsan College of Medicine, Asan Medical Center Children's Hospital, 88, Olympic-ro 43-Gil, Songpa-Gu, Seoul, 05505, Republic of Korea.

Aims: Small bowel capsule endoscopy, which has been widely used to evaluate small bowel disease, has a risk of capsule retention (CR). The present systematic review and meta-analysis evaluated the accuracy of patency capsule (PC) and cross-sectional imaging (CSI) for predicting CR.

Methods: Databases, including MEDLINE/PubMed, EMBASE, Web of Science and the Cochrane library, were searched for articles through August 15, 2023, that investigated the diagnostic accuracy of PC or CSI for predicting CR.

View Article and Find Full Text PDF

Background: Capsule endoscopy (CE) is a pivotal diagnostic tool for gastrointestinal (GI) disorders, yet capsule retention poses a significant risk, especially in patients with known risk factors. The patency capsule (PC) helps assess the functional patency of the GI tract to mitigate this risk. However, the standard 28-hour protocol for confirming patency often results in high false-positive rates, unnecessarily excluding many patients from undergoing diagnostic CE.

View Article and Find Full Text PDF

The Utility of Patency Capsule in Patients With Crohn's Disease.

J Clin Gastroenterol

October 2024

Division of Gastroenterology and Hepatology, Inflammatory Bowel Disease Center, Mayo Clinic, Jacksonville, FL.

Background: Video capsule retention is a complication that can have serious consequences in patients with Crohn's disease (CD). The patency capsule was developed to detect small bowel strictures. The usefulness of patency capsules in patients who do not have evidence of small bowel disease on imaging is uncertain.

View Article and Find Full Text PDF

Background: Neurosurgical training requires a deep understanding of brain anatomy, especially white matter fiber pathways, to enhance surgical precision. Traditional dissection techniques, such as Klingler's white matter dissection, are essential, but newer methods can provide additional clarity. This study explores the application of a fluorescent-assisted technique to improve the visualization and understanding of white matter fibers during neurosurgical training.

View Article and Find Full Text PDF

Introduction: The PillCam™ patency capsule is useful in preventing capsule endoscope retention; however, visual confirmation of patency capsule excretion is challenging for many patients.

Objective: We investigated the factors related to the patency capsule remaining in the colon after 33 h and the factors hindering the visual confirmation of its excretion.

Methods: We retrospectively analyzed 498 patients with intestinal patency who underwent patency capsule examination.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!