Measurement of Femoral Vein Diameter by Ultrasound to Estimate Central Venous Pressure.

Ann Am Thorac Soc

Division of Pulmonary and Critical Care, Hennepin County Medical Center, University of Minnesota, Minneapolis, Minnesota.

Published: January 2016

Rationale: Central venous pressure (CVP) can be estimated by ultrasound of the inferior vena cava (IVC), but imaging the IVC is sometimes challenging. The femoral vein is easily imaged by ultrasound and might therefore provide an alternate target for estimating CVP.

Objectives: To assess femoral vein diameter (FVD) measured by ultrasound imaging for estimating CVP.

Methods: We prospectively measured CVP and FVD in 97 patients. Receiver operating characteristic curves were used to assess the ability of FVD to predict specific CVP values: less than 10 mm Hg, less than 8 mm Hg (low CVP), and greater than 12 mm Hg (high CVP). Interobserver variability of FVD measurement was assessed in 20 patients.

Measurements And Main Results: There was moderate correlation between FVD and CVP (r = 0.66, P < 0.001). FVD less than or equal to 0.8 cm was the best predictor of CVP < 10 mm Hg, with an area under the curve (AUC) of 0.894 and a 95% confidence interval (CI) of 0.82 to 0.97. FVD less than or equal to 0.7 cm performed best for predicting low CVP (AUC = 0.97; 95% CI, 0.94-0.99) and FVD greater than or equal to 1.0 cm for high CVP (AUC = 0.80; 95% CI, 0.72-0.89). However, FVD greater than or equal to 1.2 cm had the greatest specificity (94%) for high CVP. Interobserver variability in FVD measurements was 8.3 ± 7.2%.

Conclusions: The results of this exploratory study suggest that the accuracy of FVD measured by ultrasound imaging for estimating CVP is comparable to that which has been reported for ultrasound measurement of IVC diameter. FVD may provide an alternative approach when the IVC is difficult to image. Additional studies on other cohorts of patients are warranted to validate our proposed FVD cutoff values for predicting low and high CVP.

Download full-text PDF

Source
http://dx.doi.org/10.1513/AnnalsATS.201506-337BCDOI Listing

Publication Analysis

Top Keywords

femoral vein
12
vein diameter
8
central venous
8
venous pressure
8
cvp
6
fvd
5
measurement femoral
4
ultrasound
4
diameter ultrasound
4
ultrasound estimate
4

Similar Publications

Objective: To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.

Methods: A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.

View Article and Find Full Text PDF

A Rare Case of Linear Phlebolith: Foreign Body Discovered in the Femoral Vein.

Case Rep Surg

January 2025

Division of Vascular Surgery, Department of Surgery, College of Medicine, King Saud University, Riyadh 11322, Saudi Arabia.

Phlebolith is a term that refers to round-shaped calcified thrombi commonly located in the pelvic region. The occurrence of dense, linear calcifications or phlebolith-like formations within the soft tissues of the lower extremities, particularly in the superficial femoral, greater saphenous, or popliteal veins, is rare. This study presents the case of a 73-year-old woman who was being evaluated for postmenopausal bleeding.

View Article and Find Full Text PDF

Proximal protection devices for carotid artery stenting - A benchtop assessment of flow reversal performance.

AJNR Am J Neuroradiol

January 2025

From the Department of Radiology (J.L., E.A.B., C.B., J.C., R.K., W.B., D.F.K), and Department of Neurologic Surgery (Y.C.S., R.K., W.B.), Mayo Clinic, Rochester, MN, United States; Department of Stroke Research (J.L.), Vall d'Hebron Research Institute, Barcelona, Spain; From the Global Institute of Future Technology (Y.L.), Shanghai Jiao Tong University, Shanghai, China; Department of Neurointerventional Radiology (J.C.), Bicetre University Hospital, Le Kremlin Bicetre, France.

Background And Purpose: Proximal protection devices, such as TransCarotid Artery Revascularization (TCAR, SilkRoad Medical, Sunnyvale), aim to yield better outcomes in carotid artery stenting (CAS) than distal protection devices by preventing plaque embolization to the brain. However, transfemoral catheters may not fully reverse flow from the external carotid artery (ECA) to the internal carotid artery (ICA). We assess a new balloon-sheath device, Femoral Flow Reversal Access for Carotid Artery Stenting (FFRACAS), for this purpose.

View Article and Find Full Text PDF

Thermoresponsive dual-network chitosan-based hydrogels with demineralized bone matrix for controlled release of rhBMP9 in the treatment of femoral head osteonecrosis.

Carbohydr Polym

March 2025

Key Lab of Modern Toxicology of Ministry of Education, Center for Global Health, School of Public Health, Nanjing Medical University, 101 Longmian Avenue, Nanjing 211166, China. Electronic address:

In an effort to mitigate or reverse the pathological progression of early-stage osteonecrosis of the femoral head (ONFH), this study employed a promising strategy that involves the sustained delivery of osteogenic factors to augment core decompression, facilitated by the use of composite hydrogels. Specifically, a hydrogel was synthesized by blending chitosan, Pluronic F-127, and tripolyphosphate, utilizing both ionic bonding and copolymer micelle cross-linking techniques. This hydrogel demonstrated exceptional biocompatibility, temperature responsiveness, pH-dependent biodegradation, and controlled release properties.

View Article and Find Full Text PDF

Objective: Intermittent pneumatic compression (IPC) is considered the standard of care for preventing venous thromboembolism (VTE) in the hospital setting. However, its widespread adoption after hospitalization has been limited due to its shortcomings in obstruction of venous valves and blood reflux. The objective of this study is to compare the effects of continuous graduated pneumatic compression (CGPC), a new device with a novel mechanism, and IPC on lower hemodynamics and the incidence of VTE in patients undergoing arthroplasty.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!