Technetium-99m DTPA does not break down during ultrasound nebulization.

Clin Physiol

Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark.

Published: April 1989

For several years aerosolized 99Tcm-DTPA has been used for studies of pulmonary permeability. Comparable results have been obtained regardless of the 99Tcm-DTPA having been nebulized in an ultrasound nebulizer or a jet nebulizer. It was therefore surprising when in a recent study it was observed that more than 90% of a commercially available 99Tcm-DTPA (Squibb) was dissociated into 99TcmO4- and DTPA during ultrasound nebulization. To verify this observation we performed chromatography of seven commercially available DTPA-labelling kits (including that of Squibb). Four different test preparations of each of the kits were analysed: (1) stock solution of 99Tcm-DTPA; (2) heated (80 degrees C) 99Tcm-DTPA; (3) 99Tcm-DTPA nebulized by a DeVilbiss ultrasound nebulizer; (4) 99Tcm-DTPA nebulized by a Varic ultrasound nebulizer. In no case were we able to demonstrate more than 1.0% reduced pertechnetate (99TcmO2) or more than 0.9% free 99TcmO4- after either heating or ultrasound nebulization. A maximum of 5.6% 99TcmO2 could be demonstrated in the stock solution if chromatography was done immediately after the preparation, but only 15 min later no more than 0.9% 99TcmO2 was present. We conclude that there is no essential chemical breakdown of 99Tcm-DTPA during ultrasound nebulization. Caution should be taken not to use the 99Tcm-DTPA until 15 min after its preparation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1475-097x.1989.tb00966.xDOI Listing

Publication Analysis

Top Keywords

ultrasound nebulization
16
99tcm-dtpa nebulized
12
ultrasound nebulizer
12
99tcm-dtpa
9
stock solution
8
ultrasound
7
technetium-99m dtpa
4
dtpa break
4
break ultrasound
4
nebulization
4

Similar Publications

Identification of lesion demarcation during thoracoscopic anatomical lesion resection is fundamental for treating children with congenital lung malformation. Existing lesion demarcations do not always meet the needs of clinical practice. This study aimed to explore the safety and efficacy of near-infrared fluorescence imaging with nebulized inhalation of indocyanine green for thoracoscopic anatomical lesion resection in children with congenital lung malformation.

View Article and Find Full Text PDF

Respiratory interventions including noninvasive ventilation, continuous positive airway pressure and high-flow nasal oxygen generated infectious aerosols may increase risk of airborne disease (SARS-CoV-2, influenza virus) transmission to healthcare workers. We developed and tested a prototype portable UV-C device to sterilize high flows of viral-contaminated air from a simulated patient source at airflow rates of up to 100 l/m. Our device consisted of a central quartz tube surrounded 6 high-output UV-C lamps, within a larger cylinder allowing recirculation past the UV-C lamps a second time before exiting the device.

View Article and Find Full Text PDF

Assessing Lung Ventilation and Bronchodilator Response in Asthma and Chronic Obstructive Pulmonary Disease with F MRI.

Radiology

December 2024

From the Translational and Clinical Research Institute, Newcastle University, Newcastle upon Tyne, United Kingdom (B.J.P., M.A.N., C.W.H., A.J.S., P.E.T.); Newcastle Magnetic Resonance Centre, Health Innovation Neighbourhood, Newcastle University, Newcastle upon Tyne NE4 5PL, United Kingdom (B.J.P., M.A.N., C.W.H., P.E.T.); Pulmonary, Lung and Respiratory Imaging Sheffield, Section of Medical Imaging and Technologies, Division of Clinical Medicine, School of Medicine and Population Health, University of Sheffield, Sheffield, United Kingdom (A.M.M., J.M.W.); Department of Respiratory Medicine, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, United Kingdom (I.F.); Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom (R.A.L.); Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, United Kingdom (H.F.F., J.N.S.M.); and Insigneo Institute, University of Sheffield, Sheffield, United Kingdom (J.M.W.).

Background Pulmonary function tests are central to diagnosis and monitoring of respiratory diseases but do not provide information on regional lung function heterogeneity. Fluorine 19 (F) MRI of inhaled perfluoropropane permits quantitative and spatially localized assessment of pulmonary ventilation properties without tracer gas hyperpolarization. Purpose To assess regional lung ventilation properties using F MRI of inhaled perfluoropropane in participants with asthma, participants with chronic obstructive pulmonary disease (COPD), and healthy participants, including quantitative evaluation of bronchodilator response in participants with respiratory disease.

View Article and Find Full Text PDF

Objectives: Pressurized IntraThoracic Aerosol Chemotherapy (PITAC) has been suggested as a new therapy for patients with malignant pleural effusion (MPE) and/or pleural metastasis (PLM). The patients have a poor prognosis with a median survival of 3 to 12 months. We present feasibility, patient safety, and cytological/histological response assessment in PITAC-treated patients with MPE and/or PLM.

View Article and Find Full Text PDF

Background: Congenital lung malformations (CLMs) are among the rare anomalies that can be diagnosed by bronchoscopy and imaging. They can cause various respiratory symptoms and complications, especially in children with congenital heart disease. This is an interesting case report of a child with a rare combination of congenital anomalies affecting the airway.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?