Communications links that utilize modulating retro-reflectors can make use of turbulence-induced fade information available at the remote data-signal terminal in order to optimize the data transfer rate. Experiments were conducted to measure the irradiance in both the direct and the retro-reflected beams. Both on-axis and off-axis components were recorded in order to further study the enhancement in the scintillation index observed in the retro-reflected beam. Measurements were made over a 1.8 km terrestrial range at AP Hill, Virginia. The degree of correlation of the received irradiance between the direct and double-passage beams is found to approach 90% on-axis and 70% outside of the Fresnel zone radius. The scintillation index in the retro-reflected beam is enhanced on-axis due to reciprocal optical paths. The measured scintillation indices, and the correlation of the retro-reflected beam with the direct beam, are compared with a point source, point scatterer, and point receiver model in the strong scintillation approximation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.54.000F96 | DOI Listing |
Sci Rep
February 2019
Institute of Physics, Zagreb, 10000, Croatia.
We report on laser cooling of neutral rubidium atoms by using a single mode of a frequency comb. Cooling is achieved on a dipole-allowed transition at 780 nm in a one-dimensional retro-reflected beam geometry. Temperatures are measured using standard time-of-flight imaging.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
November 2019
Objective: Careful screening of bilirubin level in newborns is mandatory as per American Academy of Pediatrics (2004), to reduce incidents of kernicterus and acute bilirubin encephalopathy. Although, invasive capillary collection of blood and subsequent biochemical test is considered a gold standard for jaundice detection in neonates, transcutaneous bilirubin measurement using various non-invasive instruments is also used sporadically across the globe. The major aim of this study was to develop a non-invasive spectrometry-based technique for measurement of neonatal bilirubin level as an alternative of total serum bilirubin (TSB) test without limitations of other available bilirubinometers.
View Article and Find Full Text PDFOpt Express
December 2017
Generation of nonclassical light is an essential tool for quantum optics research and applications in quantum information technology. We present realization of the source of nonclassically correlated photon pairs based on the process of spontaneous four-wave-mixing in warm atomic vapor. Atoms are excited only by a single laser beam in retro-reflected configuration and narrowband frequency filtering is employed for selection of correlated photon pairs.
View Article and Find Full Text PDFCommunications links that utilize modulating retro-reflectors can make use of turbulence-induced fade information available at the remote data-signal terminal in order to optimize the data transfer rate. Experiments were conducted to measure the irradiance in both the direct and the retro-reflected beams. Both on-axis and off-axis components were recorded in order to further study the enhancement in the scintillation index observed in the retro-reflected beam.
View Article and Find Full Text PDFIn our development of multiscale, gigapixel camera architectures, there is a need for an accurate three-dimensional position alignment of large monocentric lenses relative to hemispherical dome structures. In this work we describe a method for estimating the position of the objective lens in our AWARE-10 four-gigapixel camera using the retro-reflected signal of a custom-designed auto-stigmatic microscope. We show that although the physical constraints of the system limit the numerical aperture of the microscope probe beam to around 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!