Coronary artery fistula is an abnormal connection between one coronary artery to another coronary artery or cardiac chambers. The coronary artery fistula may cause significant shunting of blood and cause "pseudo-stenosis" or "steal phenomenon". This will also accentuate pre-existing mild-moderate de novo coronary lesions with resultant greater pressure gradient difference across the lesions. Thus, fractional flow reserve can be a useful tool to guide intervention decision on the coronary artery fistula. There are very few published reports regarding the use of FFR to assess coronary artery fistula. In fact, there is no outcome data regarding the deferment of coronary artery fistula intervention when the FFR is not physiologically significant. This case highlighted the use of FFR to evaluate the functional significance of coronary fistula in the setting of ischemia evaluation and it was proven to be safe to defer intervention with good 3 year clinical outcome. Stress adenosine myocardial perfusion imaging correlated with the FFR result.