A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel technique for identifying the fistulous point in a direct carotid-cavernous fistula. | LitMetric

The fistulous point in a direct carotid-cavernous fistula (CCF) can often be difficult to identify because of high-flow shunting. A novel technique that is useful for identifying the fistulous point is reported. A 71-year-old woman underwent endovascular therapy for a left direct CCF that presented with sudden diplopia and tinnitus. To identify the fistulous point, vertebral angiography with manual compression of the left carotid artery was attempted, as was slow injection of a contrast agent from a balloon guiding catheter, closing off the left internal carotid artery; however, the shunt flow was very rapid, and identification was not possible. Therefore, three-dimensional digital subtraction angiography of the vertebral artery was performed while also performing manual aspiration from the balloon guiding catheter, closing off the left internal carotid artery. This reduced early visualization of the cavernous sinus and enabled an aneurysm in the cavernous sinus to be clearly visualized. Embolization was performed transarterially and transvenously, and the shunt flow disappeared completely. Vertebral angiography combined with manual aspiration from a balloon guiding catheter closing off the internal carotid artery is useful for identifying the fistulous point in a direct CCF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocn.2015.06.023DOI Listing

Publication Analysis

Top Keywords

fistulous point
20
carotid artery
16
identifying fistulous
12
point direct
12
balloon guiding
12
guiding catheter
12
catheter closing
12
internal carotid
12
novel technique
8
technique identifying
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!